Impact of Prosthesis‐Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement
نویسندگان
چکیده
BACKGROUND The aim of this study was to compare left ventricular (LV) remodeling using myocardial strain between patients with severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR) with and without prosthesis-patient mismatch (PPM). METHODS AND RESULTS In a retrospective study, speckle-tracking echocardiography was used to measure global longitudinal strain (GLS) and strain rate (GLSR), circumferential strain, and rotation before and at mid-term follow-up post-TAVR. Moderate and severe PPM were defined as an effective orifice area ≤0.85 and <0.65 cm(2)/m(2), respectively. A total of 102 patients (median age, 83 years [77-88]) with severe AS were included. At 6±3 months post-TAVR, moderate and severe PPM were found in 32 (31%) and 9 (9%) patients. Patients without PPM had a significant regression in LV mass (from 134±41 to 119±38 g/m(2); P=0.001) at follow-up whereas those with PPM did not. There was a significant improvement in LV GLS (-12.8±4.0 to -14.3±4.3%; P=0.01), GLSR (-0.61±0.20 to -0.73±0.25 second(-1); P<0.001), and early diastolic strain rate (0.52±0.20 to 0.64±0.20 second(-1); P<0.001) in patients without PPM, but not in those with PPM. After adjustment for pre-TAVR ejection fraction and post-TAVR aortic regurgitation, patients without PPM had greater improvement in LV longitudinal strain parameters compared to those with PPM. After a median follow-up of 46.1 months (interquartile range, 35.4-60.8), there was no difference in survival between patients with and without PPM. CONCLUSIONS TAVR was associated with an incidence of PPM of 40%. Greater reverse LV remodeling using myocardial strain was evident in patients without PPM compared to PPM. Presence of PPM was not associated with mortality.
منابع مشابه
Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly.
OBJECTIVE After aortic valve replacement, the effects of a small functional prosthesis on the extent and pattern of regression of left ventricular hypertrophy and on clinical outcomes may be less significant in older patients with low cardiac output requirements. The objective of this study was therefore to determine whether patient-prosthesis mismatch affects left ventricular mass regression i...
متن کاملSeventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?
BACKGROUND The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) <indexed effective orifice area ≤ 0.85 cm(2)/m(2)) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. M...
متن کاملPredictors of Left Ventricular Mass Regression Following Aortic Valve Replacement
Method Randomized selection of 100 patients, underwent aortic valve replacement with a single type of bio-prosthesis (Medtronic Mosaic) for pure aortic stenosis. The study population showed that, 25/100 (25%) patients had prosthesis-patient mismatch of a moderate degree (indexed effective orifice area (IEOA) from 0.65 cm2/m2 0.85 cm2/m2). The effect of prosthesis-patient mismatch on the postope...
متن کاملTransseptal closure of left ventricular pseudoaneurysm post-transapical transcatheter aortic valve replacement.
A n 81-year-old woman presented for a scheduled 1-month follow-up after an uneventful valve-in-valve transapical transcatheter aortic valve replacement (TA-TAVR) using a 23-mm Sapien XT prosthesis (Edwards Lifesciences, Irvine, California). Although the patient remained asymptomatic after discharge, a transthoracic echocardiogram revealed a left ventricular (LV) pseudoaneurysm, with a 10-mm nec...
متن کاملHigh-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient
Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2016