Limitation of absorption-based fiber optic gas sensors by coherent reflections.

نویسندگان

  • W Jin
  • G Stewart
  • W Philp
  • B Culshaw
  • M S Demokan
چکیده

We report the noise limitation of fiber optic gas sensors with highly coherent laser sources. Interference between signal and reflected waves causes signal fluctuation in the output; this limits the performance of the sensing system. Sensor resolutions limited by coherent reflections are calculated and compared with experimental results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

COMPARISON OF DIFFERENT GLASS COMPOUNDS FOR INTRINSIC FIBER OPTIC TEMPERATURE SENSORS

Different glasses suitable for temperature sensing in the fiber optic sensors were studied in this article. The phase changes for eight different glass materials were calculated and results were compared. Our results showed that extra dense flint glass is the most sensitive one, while pure silica results in the lowest phase change. In another study the effect of wavelength on the phase variatio...

متن کامل

Research Progress on F-P Interference—Based Fiber-Optic Sensors

We review our works on Fabry-Perot (F-P) interferometric fiber-optic sensors with various applications. We give a general model of F-P interferometric optical fiber sensors including diffraction loss caused by the beam divergence and the Gouy phase shift. Based on different structures of an F-P cavity formed on the end of a single-mode fiber, the F-P interferometric optical sensor has been exte...

متن کامل

Theory of fiber-optic, evanescent-wave spectroscopy and sensors.

A general theory for fiber-optic, evanescent-wave spectroscopy and sensors is presented for straight, uncladded, step-index, multimode fibers. A three-dimensional model is formulated within the framework of geometric optics. The model includes various launching conditions, input and output end-face Fresnel transmission losses, multiple Fresnel reflections, bulk absorption, and evanescent-wave a...

متن کامل

Real-Time Analysis of Isoprene in Breath by Using Ultraviolet-Absorption Spectroscopy with a Hollow Optical Fiber Gas Cell

A breath analysis system based on ultraviolet-absorption spectroscopy was developed by using a hollow optical fiber as a gas cell for real-time monitoring of isoprene in breath. The hollow optical fiber functions as an ultra-small-volume gas cell with a long path. The measurement sensitivity of the system was evaluated by using nitric-oxide gas as a gas sample. The evaluation result showed that...

متن کامل

Acousto-Optic Q-Switched Fiber Laser-Based Intra-Cavity Photoacoustic Spectroscopy for Trace Gas Detection

We proposed a new method for gas detection in photoacoustic spectroscopy based on acousto-optic Q-switched fiber laser by merging a transmission PAS cell (resonant frequency f₀ = 5.3 kHz) inside the fiber laser cavity. The Q-switching was achieved by an acousto-optic modulator, achieving a peak pulse power of ~679 mW in the case of the acousto-optic modulation signal with an optimized duty rati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 36 25  شماره 

صفحات  -

تاریخ انتشار 1997