Tropospheric NO2 from SCIAMACHY and Zugspitze FTIR
نویسنده
چکیده
Stratospheric and tropospheric NO2 variability on the diurnal and annual scale: a combined retrieval from ENVISAT/SCIAMACHY and solar FTIR at the Permanent Ground-Truthing Facility Zugspitze/Garmisch R. Sussmann, W. Stremme, J. P. Burrows, A. Richter, W. Seiler, and M. Rettinger IMK-IFU, Forschungszentrum Karlsruhe, Garmisch-Partenkirchen, Germany Institute of Environmental Physics, University of Bremen, Bremen, Germany Received: 15 March 2005 – Accepted: 31 March 2005 – Published: 20 April 2005 Correspondence to: R. Sussmann ([email protected]) © 2005 Author(s). This work is licensed under a Creative Commons License.
منابع مشابه
Stratospheric and tropospheric NO2 variability on the diurnal and annual scale: a combined retrieval from ENVISAT/SCIAMACHY and solar FTIR at the Permanent Ground-Truthing Facility Zugspitze/Garmisch
Columnar NO2 retrievals from solar FTIR measurements at the Zugspitze (47.42 N, 10.98 E, 2964 m a.s.l.), Germany were investigated synergistically with columnar NO2 retrieved from SCIAMACHY data by the University of Bremen scientific algorithm UB1.5 for the time span July 2002–October 2004. A new concept to match FTIR data to the time of satellite overpass makes use of the NO2 daytime increasin...
متن کاملInitial validation of ENVISAT/SCIAMACHY columnar CO by FTIR profile retrievals at the Ground-Truthing Station Zugspitze
Carbon monoxide vertical profile retrievals from ground-based solar FTIR measurements at the Permanent Ground-Truthing Station Zugspitze (47.42 N, 10.98 E, 2964 m a.s.l.), Germany are used to validate columnar CO retrieved from ENVISAT/SCIAMACHY spectra (WFMDOAS version 0.4). The WFM-DOAS retrievals of CO include an empirical column scaling factor of 0.5. Therefore, not absolute column levels a...
متن کاملValidation of SCIAMACHY columnar methane by Zugspitze FTIR
Validation of ENVISAT/SCIAMACHY columnar methane by solar FTIR spectrometry at the Ground-Truthing Station Zugspitze R. Sussmann, W. Stremme, M. Buchwitz, and R. de Beek IMK-IFU, Forschungszentrum Karlsruhe, Garmisch-Partenkirchen, Germany Institute of Environmental Physics (iup), University of Bremen FB1, Bremen, Germany Received: 27 January 2005 – Accepted: 23 March 2005 – Published: 13 April...
متن کاملValidation of ENVISAT/SCIAMACHY columnar CO by FTIR profile retrievals
Validation of ENVISAT/SCIAMACHY columnar CO by FTIR profile retrievals at the Ground-Truthing Station Zugspitze R. Sussmann and M. Buchwitz IMK-IFU, Forschungszentrum Karlsruhe, Garmisch-Partenkirchen, Germany Institute of Environmental Physics (iup), University of Bremen FB1, Bremen, Germany Received: 13 July 2004 – Accepted: 13 January 2005 – Published: 3 February 2005 Correspondence to: R. S...
متن کاملFRESCO+: an improved O2 A-band cloud retrieval algorithm for tropospheric trace gas retrievals
The FRESCO (Fast Retrieval Scheme for Clouds from the Oxygen A-band) algorithm has been used to retrieve cloud information from measurements of the O2 Aband around 760 nm by GOME, SCIAMACHY and GOME2. The cloud parameters retrieved by FRESCO are the effective cloud fraction and cloud pressure, which are used for cloud correction in the retrieval of trace gases like O3 and NO2. To improve the cl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005