Self-Calibration of Camera-Equipped Robot Manipulators

نویسندگان

  • Yan Meng
  • Hanqi Zhuang
چکیده

A new approach to self-calibrate a camera-equipped robot manipulator is proposed in this paper. Self-calibration here means that the camera-robot system is capable of determining its geometric parameters without any external measurements and/or ground truth calibration data. With the proposed approach, one is able to identify all the rotational parameters and, up to a scale factor, all the translational parameters of a robotic system without any ground truth data. It is known from the computer vision literature that the extrinsic and intrinsic parameters of the camera can be obtained up to a scale factor by using the corresponding points of objects in a natural environment from an image sequence without knowing the positions of these object points. It is also well known that if the camera is treated as the tool of the robot, one is able to compute the corresponding robot pose directly from the camera-extrinsic parameters. An important question is how to determine the scale factors, which vary from one robot pose to another. It is discovered in this paper that if the robot pose measurement configurations follow a specially planned optimal trajectory, a unique scale factor can be used for all the poses measured along the trajectory. Thus, one is able to identify all the independent parameters of the robot with the poses measured in this manner with an inherently undetermined scale factor. One question remains: how do we obtain this unknown scale factor? Actually, the problem can be solved in a separate process. By two views of, say, a yardstick with the known length, the scale factor can be computed. If more than one measurement of the scale or measurements of multiple scales are provided from different viewing angles, the scale factor can be estimated with better accuracy in a least squares sense. Extensive simulation and experiment studies on a PUMA 560 robot reveal the convenience and effectiveness of the proposed approach. KEY WORDS—robot self-calibration, robot autonomous calibration, robot calibration, pose determination, camera self-calibration, motion estimation, structure from motion The International Journal of Robotics Research Vol. 20, No. 11, November 2001, pp. 909-921, ©2001 Sage Publications

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptive Camera Calibration Control of Planar Robots: Elimination of Camera Space Velocity Measurements

This paper considers the problem of position tracking control o.f planar robot manipulators via visual servoing in the presence of parametric uncertainty associated with the camera system. Specifically, by assuming exact knowledge o.f the mechanical parameters, we design an adaptive camera calibration controller that compensates for uncertain camera parameters and ensures global asymptotic posi...

متن کامل

Robotic Ultrasound Needle Placement and Tracking: Robot-to-Robot Calibration

In medicine and industry, there is a need for flexible multirobot platforms that allow for independent placement of multiple robotic manipulators. The Computer Aided Medical Procedures research group at Johns Hopkins University has developed a multi-robot surgical platform with two KUKA iiwa robotic manipulators. Each KUKA system is built into a mobile workstation, which makes them easy to tran...

متن کامل

A New Approach to Self-Localization for Mobile Robots Using Sensor Data Fusion

This paper proposes a new approach for calibration of dead reckoning process. Using the well-known UMBmark (University of Michigan Benchmark) is not sufficient for a desirable calibration of dead reckoning. Besides, existing calibration methods usually require explicit measurement of actual motion of the robot. Some recent methods use the smart encoder trailer or long range finder sensors such ...

متن کامل

Estimation and Calibration of Robot Link Parameters with Intelligent Techniques

Abstract: Using robot manipulators for high accuracy applications require precise value of the kinematics parameters. Since measurement of kinematics parameters are usually associated with errors and accurate measurement of them is an expensive task, automatic calibration of robot link parameters makes the task of kinematics parameters determination much easier. In this paper a simple and easy ...

متن کامل

Adaptive Visual Servoing of Robot Manipulators without Measuring the Image Velocity

The direct adaptive control of planar robot manipulators through visual servoing is considered. A solution is developed for image-based visual systems to allow tracking of a desired trajectory, when both camera calibration and robot dynamics are uncertain. In order to solve the MIMO parameter adaptive problem without using image velocity information, the adaptive camera calibration is formulate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • I. J. Robotics Res.

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2001