Determining the accommodative response from wavefront aberrations.
نویسندگان
چکیده
The purpose of this study was to evaluate some of the methods used to calculate objective refractions from wavefront aberrations, to determine their applicability for accommodation research. A wavefront analyzer was used to measure the ocular aberrations of 13 emmetropes and 17 myopes at distance, and 4 near target vergences: 2, 3, 4, and 5 D. The accommodative response was calculated using the following techniques: least squares fitting (Zernike defocus), paraxial curvature matching (Seidel defocus), and 5 optical quality metrics (PFWc, PFSc, PFCc, NS, and VSMTF). We also evaluated a task-specific method of determining optimum focus that used a through-focus procedure to select the image that best optimized both contrast amplitude and gradient (CAG). Neither Zernike nor Seidel defocus appears to be the best method for determining the accommodative response from wavefront aberrations. When the eye has negative spherical aberration, Zernike defocus tends to underestimate, whereas Seidel defocus tends to overestimate the accommodative response. A better approach is to first determine the best image plane using a suitable optical quality metric and then calculate the accommodative error relative to this plane. Of the metrics evaluated, both NS and VSMTF were reasonable choices, with the CAG algorithm being a less preferred alternate.
منابع مشابه
The effect of ocular aberrations on steady-state errors of accommodative response.
It is well accepted that the accommodation system is characterized by steady-state errors in focus. The purpose of this study was to correlate these errors with changes in ocular wavefront aberration and corresponding image quality when accommodating. A wavefront analyzing system, the Complete Ophthalmic Analysis System (COAS), was used in conjunction with a Badal optometer to allow continuous ...
متن کاملThe association of wavefront aberration and accommodative lag in myopes
Accommodative lags, induced by a target at 33 cm (distance-induced condition) and by a -3.0 D lens (lens-induced condition), and wavefront aberrations were measured in 27 young myopic eyes. The accommodative lags and Strehl ratios derived from the wavefront aberrations in myopes were compared with those from 57 emmetropes. Accommodation was measured using a Canon R-1 autorefractor, while aberra...
متن کاملAsymmetric Wavefront Aberrations and Pupillary Shapes Induced by Electrical Stimulation of Ciliary Nerve in Cats Measured with Compact Wavefront Aberrometer
To investigate the changes in the wavefront aberrations and pupillary shape in response to electrical stimulation of the branches of the ciliary nerves in cats. Seven eyes of seven cats were studied under general anesthesia. Trains of monophasic pulses (current, 0.1 to 1.0 mA; duration, 0.5 ms/phase; frequency, 5 to 40 Hz) were applied to the lateral or medial branch of the short ciliary nerve ...
متن کاملHuman eyes do not need monochromatic aberrations for dynamic accommodation
PURPOSE To determine if human accommodation uses the eye's own monochromatic aberrations to track dynamic accommodative stimuli. METHODS Wavefront aberrations were measured while subjects monocularly viewed a monochromatic Maltese cross moving sinusoidally around 2D of accommodative demand with 1D amplitude at 0.2 Hz. The amplitude and phase (delay) of the accommodation response were compared...
متن کاملDynamic accommodation with simulated targets blurred with high order aberrations
High order aberrations have been suggested to play a role in determining the direction of accommodation. We have explored the effect of retinal blur induced by high order aberrations on dynamic accommodation by measuring the accommodative response to sinusoidal variations in accommodative demand (1-3D). The targets were blurred with 0.3 and 1mum (for a 3-mm pupil) of defocus, coma, trefoil and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vision
دوره 10 5 شماره
صفحات -
تاریخ انتشار 2010