Phase Transformations in NiTi Endodontic Files and Fatigue Resistance

نویسندگان

  • S. Vilaverde Correia
  • F. M. Braz Fernandes
چکیده

NiTi endodontic files allow for clinical enlargement of harshly curved root canals. However, files rotated under severe flexion might fracture unexpectedly, remain inside teeth and thus, hinder treatment outcome. ProFile .06(35) are among the most commonly used rotary files. In the present study, 10 of these brand new instruments were used to perform DSC on their cutting regions and determine the amount of R-phase present at 10, 20, 37, and 65oC, both during cooling and heating programmed cycles. Another 48 new ProFile .06(35) instruments underwent rotation/flexion assays at 300 rpm and 10 mm radius of curvature. Files were divided into four groups of 12 instruments each. Each group was tested at 10, 20, 37, and 65oC. The number of cycles to fracture (Nf) and the length of the broken segment (Lf) were determined for each tested file. Results show no statistically s as for Lf in all groups. On the contrary, Nf depends highly on testing temperature: as temperature increases from 10 to 37 oC, Nf strikingly decreases; from 37 and 65 oC, no significant changes in Nf occur. As for DSC results, it is clearly shown that R-phase is most abundant at 10 oC and consistently decreases up to 37oC, both during heating and cooling; from 37 to 65 oC, the quantity of R-phase in the alloy is negligible. In conclusion, it is shown that fatigue resistance in ProFile .06(35) instruments is not only highly enhanced but also proportional to the amount of R-phase in the alloy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A numerical method for predicting the bending fatigue life of NiTi and stainless steel root canal instruments.

AIM To evaluate the bending fatigue lifetime of nickel-titanium alloy (NiTi) and stainless steel (SS) endodontic files using finite element analysis. METHODOLOGY The strain-life approach was adopted and two theoretical geometry profiles, the triangular (TR) and the square cross-sections, were considered. Both low-cycle fatigue (LCF) lifetime and high-cycle fatigue (HCF) lifetime were evaluate...

متن کامل

An overview of the mechanical properties of nickeltitanium endodontic instruments

Differences in mechanical properties between endodontic instruments might be related to the chemical composition, phase constitution, or fabrication process of nickel–titanium (NiTi) endodontic instruments. An awareness and knowledge of the mechanical properties of NiTi endodontic files and their association with the metallurgical properties is useful for clinicians to understand the behavior o...

متن کامل

Cyclic Flexural Fatigue Resistance of the Revo-s Rotary Nickel-titanium Endodontic Files

Resistance to cyclic flexural fatigue failure is an important feature of rotary nickel-titanium (NiTi) instruments. The aim of this study was to evaluate the cyclic flexural fatigue failure resistance of RevoS Shaper Universal rotary NiTi files and to compare it to two other rotary NiTi files with similar size and taper, the Hero Shaper and the ProFile. Fifteen each of Revo-S Shaper Universal, ...

متن کامل

Current Strategies in Metallurgical Advances of Rotary NiTi Instruments: A Review

NiTi alloy has been used as the raw material for making endodontic files. The interest in NiTi instrument research has not waned with time. In fact, there is a renewed interest in this field, notably through the application of modern research tools and techniques from other fields, making it a truly cross-disciplinary area of research. In 1988, Walia and colleagues introduced nickeltitanium (Ni...

متن کامل

Current Strategies in Metallurgical Advances of Rotary NiTi Instruments: A Review

NiTi alloy has been used as the raw material for making endodontic files. The interest in NiTi instrument research has not waned with time. In fact, there is a renewed interest in this field, notably through the application of modern research tools and techniques from other fields, making it a truly cross-disciplinary area of research. In 1988, Walia and colleagues introduced nickeltitanium (Ni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009