Modeling passive mechanical interaction between aqueous humor and iris.

نویسندگان

  • J J Heys
  • V H Barocas
  • M J Taravella
چکیده

Certain forms of glaucoma are associated with displacement of the iris from its normal contour. We present here a mathematical model of the coupled aqueous humor-iris system that accountsfor the contribution of aqueous humor flow and passive iris deformability to the iris contour. The aqueous humor is modeled as a Newtonian fluid, and the iris is modeled as a linear elastic solid. The resulting coupled equation set is solved by the finite element method with mesh motion in response to iris displacement accomplished by tracking a pseudo-solid overlying the aqueous humor. The model is used to predict the iris contour in healthy and diseased eyes. The results compare favorably with clinical observations, supporting the hypothesis that passive iris deformation can produce the iris contours observed using ultrasound biomicroscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accommodative microfluctuations and iris contour.

Mechanical interaction between aqueous humor, iris, and intraocular structures can alter the iris profile from its normal curvature. In particular, significant changes to the iris profile occur during accommodation as the anterior lens movement forces the iris into greater posterior bowing. We extended a previous mathematical model of the anterior segment and investigated the response of this c...

متن کامل

Fluid and structure coupling analysis of the interaction between aqueous humor and iris

BACKGROUND Glaucoma is the primary cause of irreversible blindness worldwide associated with high intraocular pressure (IOP). Elevated intraocular pressure will affect the normal aqueous humor outflow, resulting in deformation of iris. However, the deformation ability of iris is closely related to its material properties. Meanwhile, the passive deformation of the iris aggravates the pupillary b...

متن کامل

The source of proteins in the aqueous humor of the normal rabbit.

Aqueous fluorophotometric, tracer localization and modeling methods were combined to document the existence of a pathway in the normal rabbit for the diffusion of proteins from the ciliary and iridial process stromas through the iris stroma into the aqueous humor of the anterior chamber. A new custom-conjugated tracer, fluoresceinated horseradish peroxidase (F-HRP), was used. Anesthetized rabbi...

متن کامل

Aqueous humor tyrosinase activity is indicative of iris melanocyte toxicity

Antibiotics such as fluoroquinolones (FQLs) are commonly used to treat ocular infections but are also known to cause dermal melanocyte toxicity. The release of dispersed pigments from the iris into the aqueous humor has been considered a possible ocular side effect of the systemic administration of FQLs such as Moxifloxacin, and this condition is known as bilateral acute iris transillumination ...

متن کامل

Drug Transport by the Blood-Aqueous Humor Barrier of the Eye.

The ocular barriers (cornea, blood-retinal barrier, and blood-aqueous humor barrier) make treating eye diseases with therapeutic drugs challenging. The tight capillary endothelium of the iris and the ciliary body epithelium form the blood-aqueous humor barrier. The iris and ciliary body (iris-ciliary body) express a variety of drug transporters in the ATP-binding cassette and solute carrier (SL...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 123 6  شماره 

صفحات  -

تاریخ انتشار 2001