A CFD based thermo-hydraulic performance analysis of an artificially roughened solar air heater having equilateral triangular sectioned rib roughness on the absorber plate

نویسنده

  • Anil Singh Yadav
چکیده

In this article, a numerical investigation is conducted to analyze the two-dimensional incompressible Navier–Stokes flows through the artificially roughened solar air heater for relevant Reynolds number ranges from 3800 to 18,000. Twelve different configurations of equilateral triangular sectioned rib (P/e = 7.14–35.71 and e/d = 0.021–0.042) have been used as roughness element. The governing equations are solved with a finite-volume-based numerical method. The commercial finite-volume based CFD code ANSYS FLUENT is used to simulate turbulent airflow through artificially roughened solar air heater. The RNG k–e turbulence model is used to solve the transport equations for turbulent flow energy and dissipation rate. A total numbers of 432,187 quad grid intervals with a near wall elements spacing of y 2 are used. Detailed results about average heat transfer and fluid friction in an artificially roughened solar air heater are presented and discussed. The effects of grid distributions on the numerical predictions are also discussed. It has been observed that for a given constant value of heat flux (1000 W/m), the performance of the artificially roughened solar air heater is strong function of the Reynolds number, relative roughness pitch and relative roughness height. Optimum configuration of the roughness element for artificially roughened solar air heater is evaluated. 2013 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and Simulation of Turbulent Flows through a Solar Air Heater Having Square-Sectioned Transverse Rib Roughness on the Absorber Plate

Solar air heater is a type of heat exchanger which transforms solar radiation into heat energy. The thermal performance of conventional solar air heater has been found to be poor because of the low convective heat transfer coefficient from the absorber plate to the air. Use of artificial roughness on a surface is an effective technique to enhance the rate of heat transfer. A CFD-based investiga...

متن کامل

Investigating The Parameters For The Performance Enhancement Of A Solar Air Heater Having Different Artificially Roughened Geometries

The use of an artificial roughness on a surface of absorber plate is an effective technique to enhance the rate of heat transfer to fluid flow in the duct of a solar air heater. This paper presents a comparison of parameters that enhance the heat transfer coefficient thus efficiency ofa solar air heater for different artificially roughened geometries for the Reynolds number from 2500 -18000. Th...

متن کامل

CFD Analysis on the Thermal Hydraulic Performance of an SAH Duct with Multi V-Shape Roughened Ribs

Abstract: This study presents the heat transfer and fluid flow characteristics in a rib-roughened SAH (solar air heater) channel. The artificial roughness of the rectangular channel was in the form of a thin circular wire in discrete multi V-pattern rib geometries. The effect of this geometry on heat transfer, fluid flow, and performance augmentation was investigated using the CFD (computationa...

متن کامل

CFD Analysis to Study Effect of Circular Vortex Generator Placed in Inlet Section to Investigate Heat Transfer Aspects of Solar Air Heater

CFD analysis of 2-dimensional artificially roughened solar air heater duct with additional circular vortex generator, inserted in inlet section is carried out. Circular transverse ribs on the absorber plate are placed as usual. The analysis is done to investigate the effect of inserting additional vortex generator on the heat transfer and flow friction characteristics inside the solar air heate...

متن کامل

Enhancement of heat transfer coefficient using Diamond shaped roughness on the absorber plate of solar air heater

Solar collector (Air heater) has low thermal efficiency due to the low thermal conductivity between Air and absorber plate. So there is a need to enhance the thermal conductivity between air and absorber plate. This leads higher temperature to absorber plate and hence maximum thermal losses occurs to environment .It can be made possible by creating artificial roughness on absorber plate .There ...