Tilt, Decentration, and Internal Higher-Order Aberrations of Sutured Posterior-Chamber Intraocular Lenses in Patients with Open Globe Injuries
نویسندگان
چکیده
Purpose To evaluate the tilt, decentration, and internal higher-order aberrations (HOAs) of sutured posterior-chamber intraocular lenses (IOLs) in patients with open globe injuries. Methods 46 consecutive patients (47 eyes) who underwent transsclerally sutured IOL implantation were enrolled in this prospective cohort study. Nineteen eyes had a history of open globe injury. The tilt and decentration of the IOLs and the visual quality were measured 1 month after surgery. Results The horizontal tilt and decentration of the IOLs in the open-globe-injury group were significantly higher than those in the control group (both P < 0.05). In the open-globe-injury group, the horizontal decentration was significantly greater in the limbus-sclera-involved group (n = 11) than in the only-cornea-involved group (n = 8, P = 0.040). The internal coma, 3rd-order, and total HOA values at pupil sizes of 4 mm (P = 0.006) and 6 mm (P = 0.013) were significantly higher in the open-globe-injury group than in the controls. Consequently, the optical quality data for the modulation transfer function and the Strehl ratio (all P < 0.05) were significantly poorer in the open-globe-injury group. Conclusions Open globe injuries damage the structural integrity of the eyeball, resulting in more-misaligned sutured IOLs and poorer visual quality.
منابع مشابه
Intraocular lens alignment from purkinje and Scheimpflug imaging.
The improved designs of intraocular lenses (IOLs) implanted during cataract surgery demand understanding of the possible effects of lens misalignment on optical performance. In this review, we describe the implementation, set-up and validation of two methods to measure in vivo tilt and decentration of IOLs, one based on Purkinje imaging and the other on Scheimpflug imaging. The Purkinje system ...
متن کاملComplications after primary and secondary transsclerally sutured posterior chamber intraocular lens implantation.
This retrospective study analyses and compares early complications during the first month after primary and secondary posterior chamber implantation of transsclerally sutured IOL. The analysis covered medical records of 65 patients who underwent posterior chamber implantation of transsclerally sutured IOL at the Eye Clinic in Rijeka between 1998 and 2003. In 30 patients (group 1) lenses were im...
متن کاملکاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار
Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...
متن کاملCustomized computer models of eyes with intraocular lenses.
We compared experimental wave aberrations in pseudophakic eyes with aspheric intraocular lenses (IOLs) to simulate aberrations from numerical ray tracing on customized computer eye models using corneal topography, angle lambda, ocular biometry, IOL geometry, and IOL tilt and decentration measured on the same eyes. We found high correlations between real and simulated aberrations even for the ey...
متن کاملTilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.
PURPOSE To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. SETTING Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. METHODS Measurements of IOL tilt and decentration were obtained using a commercial Schei...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017