Variable-Size Injectable Dialysis Chambers

ثبت نشده
چکیده

We required a disposable dialysis chamber of approximately 100 μL internal volume to fit within a small reaction vial. Since our application demanded the highest possible rate of diffusion into and out of the chamber, the surface area-to-volume ratio had to be as high as was practical. Injectable dialysis chambers are commercially available, e.g., the Slide-A-Lyzer® Cassette (Pierce, Rockford, IL, USA). However, they are relatively expensive and the outside dimensions too bulky (7 × 40 × 40 mm) for our application. The device described here uses washers cut from silicone rubber, with dialysis membrane glued to both faces. While the devices are more complicated to construct than other small dialysis chambers described recently (1), they afford an increased flexibility in size. Washers were cut from 1.6-mmthick translucent silicone rubber, of high tensile strength (1100 psi) and medium hardness (McMaster-Carr, Chicago, IL, USA) with handheld punches. No smoothing of cut edges was required. The washers had an external diameter of 15.9 mm and an internal diameter of 9.5 mm. A small amount of Super Glue was spread over one side of a washer, which was then glued onto a sheet of Spectra/Por® Dialysis Membrane (MWCO: 12 000– 14000; Spectrum, Laguna Hills, CA, USA) (Figure 1, left panel). Even pressure applied over the entire washer (with, in our case, the base of a handheld 7-mL plastic scintillation vial) for 10–15 s results in a good seal. The resulting half-finished devices were cut from the dialysis membrane, and the gluing process was repeated on the other side to create a chamber with an internal volume of approximately 110 μL. Construction was completed by cutting each chamber from the sheet. Dialysis chambers can be constructed to any size, using a variety of thicknesses of silicone rubber and diameters of the punches. With the punches available to us and 1.6-mm silicone rubber, we can easily make dialysis chambers with up to 900 μL internal volume. This could be increased by cementing two half-finished dialysis chambers together or by using thicker silicone rubber. The width of the glued surface of the rubber needs to be sufficient to provide satisfactory bonding. We found that a width of 3 mm was sufficient to ensure a good seal. Flat sheets of dialysis membrane were used not only for ease but also to avoid the creases in the membrane found in tubular dialysis membranes, which are difficult, if not impossible, to glue across sufficiently tightly to prevent failure of the seal. The glue was not affected by the Tris buffers that were used, and the chambers maintained their integrity overnight in small vials in a shaking water bath. Samples (100 μL) were injected into the chambers using a 1-cc insulin syringe with micro-fine IV needle (Becton Dickinson Labware, Bedford, MA, USA). The fine-gauge needles were required to penetrate the very thin chamber walls (1.6-mm thickness). Some stretching of the membrane results if the sample is introduced prior to evacuating the air in the chamber. To avoid this stretching, it is possible to evacuate air from the chamber before injection of the sample by carefully drawing back on the syringe plunger. To completely exclude air bubbles from the chamber, it is necessary to remove the needle from the chamber after evacuation, expel the air from the syringe needle,

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Isoflurane Anesthesia Induction System for Raccoons

We developed a novel small-volume (24-L) conical-shaped isoflurane anesthesia induction chamber for use in a den chamber and tested it along with 3 conventional stand-alone induction chambers (2 clear acrylic plastic chambers and a cylindrical-shaped chamber) to determine utility for daily short-duration manipulations of captive raccoons (Procyon lotor). Although the conventional chambers were ...

متن کامل

Survival of Dialysis Patients Using Random Survival Forest Model in Low-Dimensional Data with Few-Events

Background:Dialysis is a process for eliminating extra uremic fluids of patients with chronic renal failure. The present study aimed to determine the variables that influence the survival of dialysis patients using random survival forest model (RSFM) in low-dimensional data with low events per variable (EPV). Methods:In this historical cohort study, infor...

متن کامل

A new gradient based variable step-size LMS algorithm

A new gradient-based variable step-size LMS algorithm (VSSLMS) is proposed in this paper. The step size of the proposed algorithm is proportional to the squared norm of the smoothed gradient vector, which is a proximity measure of the adaptive process. In comparison with the existing methods, the proposed VSSLMS algorithm has improved convergence properties. Furthermore, the parameter choice of...

متن کامل

Characterization of Lithium Ion Transport Via Dialysis Process

Dialysis is a membrane based separation process in which the concentration gradient across the membrane is the driving force resulting in a flow of material from one side <span style="font-size: 10pt; ...

متن کامل

National surveillance of dialysis-associated diseases in the United States, 2001.

In December 2001, all U.S. chronic hemodialysis (HD) centers were surveyed regarding selected patient care practices and dialysis-associated diseases. The results were compared with similar surveys conducted in previous years. During 1997-2001, the percentage of patients vaccinated against hepatitis B virus (HBV) infection increased from 47% to 60% and the percentage of staff vaccinated increas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999