Assessment of Airway Distensibility by the Forced Oscillation Technique: Reproducible and Potentially Simplifiable
نویسندگان
چکیده
A non-invasive index of airway distensibility is required to track airway remodeling over time. The forced oscillation technique (FOT) provides such an index by measuring the change in respiratory system conductance at 5 Hz over the corresponding change in lung volume (ΔGrs5/ΔVL). To become useful clinically, this method has to be reproducible and easy to perform. The series of breathing maneuvers required to measure distensibility would be greatly facilitated if the difficulty of breathing below functional residual capacity (FRC) could be precluded and the number of maneuvers could be reduced. The distensibility at lung volumes below FRC is also reduced by several confounders, suggesting that excluding data points below FRC should provide a better surrogate for airway remodeling. The objectives of this study were to investigate the reproducibility of airway distensibility measured by FOT and to assess whether the method could be simplified to increase feasibility. Distensibility was measured at three separate occasions in 13 healthy volunteers. At each visit, three deflationary maneuvers were performed, each consisting of tidal breathing from total lung capacity (TLC) to residual volume by slowly decreasing the end-expiratory volume on each subsequent breath. Distensibility was calculated by using either all data points from TLC to residual volume (RV) or only data points from TLC to FRC for either all three or only the first two deflationary maneuvers. Intra-class correlation coefficients (ICC) were used to assess reproducibility and Bland-Altman analyses were used to assess the level of agreement between the differently calculated values of distensibility. The results indicate that distensibility calculated using all data points is reproducible (ICC = 0.64). Using data points from TLC to FRC slightly improved reproducibility (ICC = 0.68) and increased distensibility by 19.4%, which was expected as distensibility above FRC should not be affected by confounders. Using only data points within the first two maneuvers did not affect reproducibility when tested between TLC and FRC (ICC = 0.66). We conclude that a valuable measure of airway distensibility could potentially be obtained with only two deflationary maneuvers that do not require breathing below FRC. This simplified method would increase feasibility without compromising reproducibility.
منابع مشابه
Effect of airway smooth muscle tone on airway distensibility measured by the forced oscillation technique in adults with asthma.
Airway distensibility appears to be unaffected by airway smooth muscle (ASM) tone, despite the influence of ASM tone on the airway diameter-pressure relationship. This discrepancy may be because the greatest effect of ASM tone on airway diameter-pressure behavior occurs at low transpulmonary pressures, i.e., low lung volumes, which has not been investigated. Our study aimed to determine the con...
متن کاملForced oscillation technique for determination of resistance to breathing in children.
Cogswell, J. J. (1973). Archives of Disease in Childhood, 48, 259. Forced oscillation technique for determination of resistance to breathing in children. A method for measuring total respiratory resistance (RT) using a forced oscillation technique was applied to children between 3 and 12 years of age. RT at midinspiration was higher than airway resistance (Raw) measured on the same children by ...
متن کاملA system to generate simultaneous forced oscillation and continuous positive airway pressure.
Assessment of airway obstruction in patients with obstructive sleep apnoea (OSA) subjected to continuous positive airway pressure (CPAP) may be carried out using the forced oscillation technique (FOT). To facilitate routine application of forced oscillation (FO) in sleep studies, our aim was to design a system capable of generating CPAP and applying FOT simultaneously. We constructed a prototyp...
متن کاملImaging lung tissue oscillations using high-speed X-ray velocimetry.
This work utilized synchrotron imaging to achieve a regional assessment of the lung's response to imparted oscillations. The forced oscillation technique is increasingly being used in clinical and research settings for the measurement of lung function. During the forced oscillation technique, pressure oscillations are imparted to the lungs via the subjects' airway opening and the response is me...
متن کاملThe forced oscillation technique in clinical practice: methodology, recommendations and future developments.
The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mechanics. FOT employs small-amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory manoeuvres. The present European Respiratory Society Task Force Report ...
متن کامل