A randomized trial comparing the Ambu ® Aura-i ™ with the air-Q ™ intubating laryngeal airway as conduits for tracheal intubation in children.

نویسندگان

  • Narasimhan Jagannathan
  • Lisa E Sohn
  • Amod Sawardekar
  • Jason Gordon
  • Ravi D Shah
  • Isabella I Mukherji
  • Andrew G Roth
  • Santhanam Suresh
چکیده

OBJECTIVES To assess the clinical performance of the Ambu Aura-i (Aura-i) in children. AIM To compare the Aura-i with the air-Q intubating laryngeal airway (air-Q) for the purposes of fiberoptic-guided tracheal intubation. BACKGROUND The Aura-i is a new supraglottic airway designed for tracheal intubation. MATERIALS/METHODS One hundred twenty children, ages 1 month to 6 years, were randomized to receive either the Aura-i or air-Q, and divided into three equal subgroups (Group 1, 2, 3) based on weight. The time for successful tracheal intubation was primarily assessed. The ease, time, and number of attempts for successful device insertion, leak pressures, fiberoptic grade of laryngeal view, number of attempts time for removal of the device after tracheal intubation, and complications were secondarily assessed. RESULTS Device placement, tracheal intubation, and removal after tracheal intubation were successful in all patients. There were no differences in the time to successful tracheal intubation through the Aura-i (32.9 ± 13.3 s), and the air-Q (33.9 ± 13 s; P = 0.68), or fiberoptic grade of view between devices. There was not a statistically significant correlation between the time to intubation and the fiberoptic grade of laryngeal view in any of the groups. There were no statistically significant differences in the overall leak pressures, air-Q (18.3 ± 6.1 cm H(2) O) vs Aura-i (16 ± 5.1 cm H(2) O; P = 0.05). In Group 1 (5-10 kg), leak pressures were higher with the air-Q (23.4 ± 7.2 cm H(2) O) than the Aura-i (16.1 ± 5.2 cm H(2) O; P = 0.001). There were no statistically significant differences in the time for removal between the two devices (P = 0.11). However, with the size 1.5 Aura-i, the pilot balloon of the tracheal tube was removed in order to facilitate the removal of the device after tracheal intubation. CONCLUSIONS Both devices served as effective conduits for fiberoptic-guided tracheal intubation. The limitation of the narrower proximal airway tube of the size 1.5 Aura-i should be considered if cuffed tracheal tubes are to be utilized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The new air-Q intubating laryngeal airway for tracheal intubation in children with anticipated difficult airway: a case series.

The air-Q intubating laryngeal airway (ILA) is a new supraglottic airway device which may overcome some limitations inherent to the classic laryngeal mask airway for tracheal intubation. We present a case series of patients with anticipated difficult airway in whom the air-Q ILA was successfully used as a conduit for fiberoptic intubation.

متن کامل

مقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(TIVA) Comparing Air Way Resistance and Dynamic Compliance of Tracheal Tube and Laryngeal Tube in TIVA

    Background & Aim: The aim of this study was to compare air way resistance and dynamic compliance of tracheal tube and laryngeal tube in TIVA(Total Intravenous Anesthesia). Nowadays, low airway resistance and dynamic compliance improvement during the mechanical ventilation whether in ICU or during general anesthesia, especially in patients with pulmonary diseases, is a favorable purpose to c...

متن کامل

The i-gel Supraglottic Airway as a Conduit for Fibreoptic Tracheal Intubation - A Randomized Comparison with the Single-use Intubating Laryngeal Mask Airway and CTrach Laryngeal Mask in Patients with Predicted Difficult Laryngoscopy.

Fibreoptic intubation through a supraglottic airway is an alternative plan for airway management in difficult or failed laryngoscopy. The aim of this study was to compare three supraglottic airways as conduits in patients with at least one predictor for difficult laryngoscopy. The i-gel was compared with the single-use intubating laryngeal mask airway (sILMA) and CTrach laryngeal mask in 120 ad...

متن کامل

Use of the air-Q intubating laryngeal airway for rapid-sequence intubation in infants with severe airway obstruction: a case series.

We describe a four-step method for fibreoptic-guided, rapid-sequence tracheal intubation through the air-Q intubating laryngeal airway in infants with severe airway obstruction. Our step-wise process provides an organised and controlled approach to safely securing the airway.

متن کامل

A comparative Study of Tracheal Intubation through i-gel® and Intubating

In this prospective randomized study, success rate of blind tracheal intubation through two different supraglottic airway devices viz. i-gel ® and the intubating laryngeal mask airway (ILMA)® was compared a using conventional polyvinylchloride endotracheal tubes. Eighty patients undergoing elective surgery under general anaesthesia were randomized in two groups comprising of 40 patients each to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Paediatric anaesthesia

دوره 22 12  شماره 

صفحات  -

تاریخ انتشار 2012