Strategies for Film Replacement in Radiography - a comparative study -

نویسندگان

  • Uwe Ewert
  • Uwe Zscherpel
چکیده

The NDT community discusses about effective film replacement by Computed Radiography (CR) and Digital Detector Arrays (DDA), also known as flat panel detectors, since more than 10 years. Several standards were published by CEN, ASTM and ASME to support the application of phosphor imaging plates in lieu of X-ray film in the year 2005. The European Community funds the project FilmFree, which supports the save change from classical film radiography to digital radiology. Thirty three companies and institutes test the ability of the new technologies and develop guidelines and standards. One of the key concepts is the usage of signal-to-noise (SNR) measurements as equivalent to the optical density of film. The procedure will be demonstrated. The application of DDAs is not yet supported by any standard, but proposals are under discussion to guide the user for correct qualification and practice. A comparative study presents the results of film replacement by CR and DDAs for welds. New strategies for correct DDA calibration yield an extra ordinary increase of image quality. The contrast sensitivity was enhanced up to 10 times in relation to film radiography. This could not yet be achieved by any other technology. The digital radiographic technique is nowadays limited by the materials grain structure and not the detector contrast-to-noise distribution. Even restrictions in the spatial unsharpness provoked by the individual picture element size of the detector are compensated by the increased contrast sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strategies for Film Replacement in Radiography - Films and Digital Detectors in Comparison -

The NDT community has discussed about effective film replacement by Computed Radiography (CR) and the new Digital Detector Arrays (DDA), also known as flat panel detectors, since more than 10 years. Several standards were published by CEN, ASTM and ASME to support the application of phosphor imaging plates in lieu of X-ray film in the year 2005. One of the key concepts is the usage of signal/no...

متن کامل

In vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection

Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of im‌age quality and elimination of processing, it has been extensively used in different fields of denti‌stry in recent years. The purpose of this study wa...

متن کامل

Strategies Used in the Translation of Interlingual Subtitling

This study was an attempt to identify the interlingual strategies employed to translate English subtitles into Persian and to determine their frequency, as well. Contrary to many countries, subtitling is a new field in Iran. The study, a corpus-based, comparative, descriptive, non-judgmental analysis of an English-Persian parallel corpus, comprised English audio scripts of five movies of differ...

متن کامل

Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...

متن کامل

Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007