Wear of composite ceramics in mixed‐material combinations in total hip replacement under adverse edge loading conditions

نویسندگان

  • Mazen Al‐Hajjar
  • Silvia Carbone
  • Louise M. Jennings
  • Sabine Begand
  • Thomas Oberbach
  • Daniel Delfosse
  • John Fisher
چکیده

Ceramic composites have performed very well under adverse edge loading conditions when used in like-on-like configurations, where the femoral head and acetabular cup are of the same material. The aim of this study was to determine the wear of pure alumina (Al2 O3 ), alumina toughened zirconia (ATZ) and zirconia toughened alumina (ZTA) when used in mixed bearing combinations, under edge loading conditions due to translational mal-positioning. The head-on-cup configurations of three ceramic materials were ATZ-on-ZTA, ZTA-on-ATZ, Al2 O3 -on-ATZ, ATZ-on-Al2 O3 , Al2 O3 -on-ZTA, and ZTA-on-Al2 O3 . They were tested on the Leeds II hip simulator under microseparation conditions. The bedding in and steady state wear rates of ATZ-on-ZTA were 1.16mm3 /million cycles and 0.18mm3 /million, respectively, and for ATZ-on-Al2 O3 were 0.66 mm3 /million cycles and 0.20 mm3 /million, respectively. The wear rates of the other bearing combinations under these adverse microseparation conditions, Al2 O3 -on-ATZ, Al2 O3 -on-ZTA, ZTA-on-ATZ and ZTA-on-Al2 O3 were very low with no clear bedding in and steady state phases, and with steady state wear rates lower than 0.11 mm3 /million. The mixed material combinations tested in this study have shown slightly higher wear rates when compared to ATZ in like-on-like configuration reported previously, but superior wear resistance when compared to alumina-on-alumina bearings tested previously under the same adverse microseparation conditions. © 2016 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1361-1368, 2017.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Influence of Edge Loading on the Wear of Fourth Generation Ceramic-on-Ceramic Bearing in Total Hip Replacements

INTRODUCTION Ceramic-on-ceramic (CoC) bearings in total hip replacements (THR) have become of great interest due to the substantial improvements in the manufacturing techniques and material properties [1]. They have substantially lower wear rates than metal or ceramic on polyethylene bearings [2] and wear particles were found to be less biologically active than particles produced by other types...

متن کامل

Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions

Edge loading can negatively impact the biomechanics and long-term performance of hip replacements. Although edge loading has been widely investigated for hard-on-hard articulations, limited work has been conducted for hard-on-soft combinations. The aim of the present study was to investigate edge loading and its effect on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip ...

متن کامل

Wear Loss Evaluation of Silicon Nitride-Hexagonal Boron Nitride Composite using Taguchi Method

Biomaterials in body environment are expected to work satisfactorily, where the pH value of body fluid varies from 1 to 9. Friction, wear, and lubrication of artificial joints are an important consideration to optimise the performance of these man-made joints to improve its function and life. The first metal-on-metal (CoCr-CoCr) total hip replacement (THR) was unsatisfactory because of high fri...

متن کامل

Wear of Polyethylene against Metal-ceramic Composite Femoral Component: Effect of Aggressive Kinematic Conditions

INTRODUCTION Zirconium is a metal with excellent biocompatibility, which when oxidized is converted to the ceramic, zirconia. Composite-bearing materials have recently become available consisting of a metal zirconium core with an oxidized zirconia surface. The metal-ceramic composite has the wear characteristics of a ceramic bearing but with a much lower propensity for fracture. This dual advan...

متن کامل

Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions

Metal-on-metal (MoM) bearings have shown low-wear rates under standard hip simulator conditions; however, retrieval studies have shown large variations in wear rates and mechanisms. High-wear in vivo has caused catastrophic complications and has been associated with steep cup-inclination angle (rotational malpositioning). However, increasing the cup-inclination angle in vitro has not replicated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 105  شماره 

صفحات  -

تاریخ انتشار 2017