Stability of lisinopril in two liquid dosage forms.

نویسندگان

  • Milap C Nahata
  • Richard S Morosco
چکیده

BACKGROUND Lisinopril is used in pediatric patients with hypertension. It is not commercially available as a liquid. Little is known about the stability of lisinopril in extemporaneously prepared liquid dosage forms. OBJECTIVE To determine the stability of lisinopril in 2 oral suspensions stored at 4 and 25 degrees C in plastic prescription bottles. METHODS Five bottles contained methylcellulose 1%:simple syrup NF (1:13) and the other 5 bottles had Ora Plus-Ora Sweet (1:1) at a lisinopril concentration of 1 mg/mL. Three samples were collected from each bottle at 0, 7, 14, 28, 42, 56, 70, and 91 days and analyzed by stability-indicating HPLC analytical method (n = 15). RESULTS At 4 degrees C, the mean +/- SD concentration of lisinopril remained >95.1 +/- 1.8% of the initial concentration in the methylcellulose formulation and 95.1 +/- 3.2% of the initial concentration in the Ora Plus-Ora Sweet formulation throughout the 91-day study period. At 25 degrees C, the mean concentration of lisinopril remained >92.4 +/- 2.2% of the initial concentration in the methylcellulose formulation for 8 weeks and 95.8 +/- 2.3% of the initial concentration in the Ora Plus-Ora Sweet formulation throughout the 91-day study period. No changes in physical appearance in any samples were seen during this period. CONCLUSIONS Lisinopril can be prepared in either of 2 liquid dosage forms and stored for at least 13 weeks under refrigeration and 8 weeks at room temperature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of Rp-hplc Method for Simultaneous Estimation of Lisinopril and Amlodipine Besylate in Tablet Dosage Form

A simple, specific, precise, and accurate reversed-phase HPLC method was developed and validated for simultaneous estimation of lisinopril and amlodipine besylate in tablet dosage forms. The separation was achieved by Hypersil ODS-BP C18 column (250 mm × 4.6 mm; 5.0 μm) using methanol: phosphate buffer at pH 6 adjusted with orthophosphoric acid (30: 70, v/v) as eluent, at a flow rate of 1 mL/mi...

متن کامل

Influence of tablet splitting on content uniformity of lisinopril/hydrochlorthiazide tablets.

Dose-related adverse effects of medications are a major problem in modern medical practice. The "correct" dose, based on drug company guidelines in package inserts, may not be correct for many patients. Tablet splitting or dividing has been an accepted practice for many years as a means of obtaining the prescribed dose of medication. As model tablets for this investigation, two batches of lisin...

متن کامل

Development of Analytical Method for Determination of Lisinopril Tablets Using Rp-hplc Method

A high performance liquid chromatographic method was developed, validated and applied for determination of lisinopril in pharmaceutical formulations. A LiChrospher RP-18 (10 μm, 250x 4 mm) column was used with a mobile phase consisting of acetonitrile: phosphate buffer (30: 70% v/v, pH 2.0), a quantitative evaluation was performed at 215 nm with flow rate of 1 mL/min, and column cooler temperat...

متن کامل

A Validated Rp-hplc Method for Simultaneous Estimation of Amlodipine and Lisinopril in Pharmaceutical Dosage Form

A reverse phase high performance liquid chromatography (RP-HPLC) method for the simultaneous estimation of amlodipine and lisinopril in marketed formulation is developed. The determination was carried out on a Phenomenex C18 (250 x 4.6 mm, 5 μm) column using a mobile phase of 0.02 M phosphate buffer solution: methanol (75:25v/v, pH 7.0). The flow rate was 1.0ml/min with detection at 212 nm. The...

متن کامل

Development of validated stability-indicating chromatographic method for the determination of fexofenadine hydrochloride and its related impurities in pharmaceutical tablets

A simple reversed phase high performance liquid chromatographic method with diode array detector (HPLC-DAD) has been developed and subsequently validated for the determination of fexofenadine hydrochloride (FEX) and its related compounds; keto fexofenadine (Impurity A), meta isomer of fexofenadine (Impurity B), methyl ester of fexofenadine (Impurity C) in addition to the methyl ester of ketofex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of pharmacotherapy

دوره 38 3  شماره 

صفحات  -

تاریخ انتشار 2004