Reagent Tracker Dyes Permit Quality Control for Verifying Plating Accuracy in ELISPOT Tests
نویسندگان
چکیده
ELISPOT assays enable the detection of the frequency of antigen-specific T cells in the blood by measuring the secretion of cytokines, or combinations of cytokines, in response to antigenic challenges of a defined population of PBMC. As such, these assays are suited to establish the magnitude and quality of T cell immunity in infectious, allergic, autoimmune and transplant settings, as well as for measurements of anti-tumor immunity. The simplicity, robustness, cost-effectiveness and scalability of ELISPOT renders it suitable for regulated immune monitoring. In response to the regulatory requirements of clinical and pre-clinical immune monitoring trials, tamper-proof audit trails have been introduced to all steps of ELISPOT analysis: from capturing the raw images of assay wells and counting of spots, to all subsequent quality control steps involved in count verification. A major shortcoming of ELISPOT and other related cellular assays is presently the lack of audit trails for the wet laboratory part of the assay, in particular, the assurance that no pipetting errors have occurred during the plating of antigens and cells. Here, we introduce a dye-based reagent tracking platform that fills this gap, thereby increasing the transparency and documentation of ELISPOT test results.
منابع مشابه
Ground Testing Strategies for Verifying the Slew Rate Tolerance of Star Trackers
The performance of a star tracker is largely based on the availability of its attitude solution. Several methods exist to assess star tracker availability under both static and dynamic imaging conditions. However, these methods typically make various idealizations that can limit the accuracy of these results. This study aims to increase the fidelity of star tracker availability modeling by acco...
متن کاملCommutability limitations influence quality control results with different reagent lots.
BACKGROUND Good laboratory practice includes verifying that each new lot of reagents is suitable for use before it is put into service. Noncommutability of quality control (QC) samples with clinical patient samples may preclude their use to verify consistency of results for patient samples between different reagent lots. METHODS Patient sample results and QC data were obtained from reagent lo...
متن کاملNano silica chromic acid/wet SiO2 and NaNO2 as an efficient reagent system for synthesis of azo dyes based on 1-naphthol at room temperature and solvent-free conditions
A convenient, rapid, and one-pot method for the synthesis of azo dyes has been developed. In this protocol, diazotization reagent (ArN2+ -CrO3–SiO2) was prepared via grinding of aromatic amines, NaNO2, wet SiO2 and nano silica chromic acid (Nano-SCA) without solvent at room temperature. The obtained diazotization reagent was suff...
متن کاملNano silica chromic acid/wet SiO2 and NaNO2 as an efficient reagent system for synthesis of azo dyes based on 1-naphthol at room temperature and solvent-free conditions
A convenient, rapid, and one-pot method for the synthesis of azo dyes has been developed. In this protocol, diazotization reagent (ArN2+ -CrO3–SiO2) was prepared via grinding of aromatic amines, NaNO2, wet SiO2 and nano silica chromic acid (Nano-SCA) without solvent at room temperature. The obtained diazotization reagent was suff...
متن کاملBi(NO3)3.5H2O: An efficient acidic reagent for synthesis of azo dyes at room temperature
An one-pot method has been developed for the synthesis of azo dyes via sequential diazotization–diazo coupling of aromatic amines with coupling agents at room temperature in the presence of Bi(NO3)3. 5H2O. Short reaction times, high yields, a clean process, simple methodology, easy work-up and green conditions are advantages of this protocol.
متن کامل