Evaluation of a Portable Monitor (Watch-PAT100) and Implications for Clinical Guidelines for the Use of Portable Monitors in Diagnosing OSAS

نویسندگان

  • J. Peter van Maanen
  • Antonius A.J. Hilgevoord
  • Nico de Vries
چکیده

Objective: To evaluate, industry independently, the accuracy of the Watch-PAT100 system (WP100) [Itamar Medical; Caesarea, Israel], a portable home sleep test, compared to polysomnography, the gold standard for diagnosing obstructive sleep apnea syndrome. Methods: Prospective clinical trial. 27 patients (24 male, 3 female) were evaluated at our institution's sleep laboratory. The apnea hypopnea index and oxygen desaturation index were used to compare the 2 testing modalities. Results: Non-parametrical testing showed a Kendall's tau = 0.685 for apnea hypopnea index and 0.748 for oxygen desaturation index. We found that the WP100 system overestimated the severity of obstructive sleep apnea syndrome in 33% when compared to polysomnography. The test-agreement was in particular poor when the WP100 indicated moderate to severe obstructive sleep apnea syndrome. Conclusion: The WP100 seems accurate for classification of obstructive sleep apnea syndrome severity up to a WP100measured apnea hypopnea index of 15. In patients with an apnea hypopnea index of more than 15 as measured with the WP100, additional polysomnography should be performed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Portable monitoring in sleep apnoea: the way forward?

P opulation-based epidemiological studies estimate the prevalence of obstructive sleep apnoea syndrome (OSAS) to be at least 2% of adult females and 4% of adult males in the developed world based on an apnoea/ hypopnoea frequency (AHI) of .5 events?h-1 associated with excessive daytime sleepiness. However, a substantial proportion of these individuals are undiagnosed [1–3]. Furthermore, it is v...

متن کامل

An Experimental Investigation of Enclosure’s Effect on Noise Reduction in Portable Generators (Technical Note)

The portable generators are the main means of compensating the shortage of national electricity power as in Iraq. However, their noise causes a huge disturbance, uncomforting and loss of concentration of the nearby resident. This problem requires a solution because most shops and residential houses use generators. Covering method is a simple and relatively low cost one for reduction of generato...

متن کامل

Using 137Cs Technique to Investigate Soil Redistribution Rates by Portable HPGe (Case Studies, Kachik Paired Subcatchments)

137Cs technique for determining soil particles redistribution is of tremendous importance considered by most soil and water conservation experts. Due to time and monetary limitations for spectrometry in the lab, a portable High Pure Germanium Detector was used in this study. For this, Kachik paired subcatchments were chosen and 60 positions in each subcatchment were used for spectrometry analys...

متن کامل

Evaluation of a portable device based on peripheral arterial tone for unattended home sleep studies.

BACKGROUND Diagnosis of obstructive sleep apnea syndrome (OSAS) by ambulatory systems is a growing practice in view of the large number of patients awaiting correct diagnosis. The Watch PAT100 (WP100) [Itamar Medical; Caesarea, Israel] is a portable device based on the peripheral arterial tone (PAT) signal, and is designed for unattended home sleep studies. OBJECTIVES To evaluate the efficacy...

متن کامل

An Android Application for Estimating Muscle Onset Latency using Surface EMG Signal

Background: Electromyography (EMG) signal processing and Muscle Onset Latency (MOL) are widely used in rehabilitation sciences and nerve conduction studies. The majority of existing software packages provided for estimating MOL via analyzing EMG signal are computerized, desktop based and not portable; therefore, experiments and signal analyzes using them should be completed locally. Moreover, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012