Comparison of Analysis Methods for Ammonia from Swine Production Facilities
نویسندگان
چکیده
This study was performed to evaluate the accuracy, validation and applicability of UV spectrophotometer (UV), Ion Chromatography (IC), and Detector tube (DT) methods for measuring ammonia (NH3) concentration in a swine confinement house and swine slurry storage tank. The mean values of NH3 emitted from the house and slurry were 5.333 ppm and 42.192 ppm for the IC method; 4.13 ppm and 36.29 ppm for the Detector tube; and 5.417 ppm and 34.193 ppm for the UV method. The accuracy and the correlation of an ammonia level analyzed by the IC method compared to the UV method were 98% and 0.998(R) in the swine confinement house and 94% and 0.997(R) in the swine slurry storage tank. On the other hand, those of ammonia level measured by the Detector tube compared to the UV method were 77% and 0.957(R) in the swine confinement house and 82% and 0.941(R) in the swine slurry storage tank. This indicated that the accuracy and the correlation of the IC method compared to the UV method were higher than those of the Detector tube method compared to the UV method. Therefore, it was concluded that the IC method was more accurate in measuring ammonia concentration in a swine house and a swine slurry storage tank. The Detector tube method should not be applied to the swine slurry storage tank in which ammonia concentration is generally higher than 30 ppm because low accuracy is caused by a gross space between scales inscribed in the Detector tube. (Asian-Aust. J. Anim. Sci. 2004. Vol 17, No. 11 : 1608-1614)
منابع مشابه
Ammonia and hydrogen sulfide emissions from swine production facilities in North America: a meta-analysis.
Literature on NH3 and H2S emissions from swine production facilities in North America was reviewed, and a meta-analysis was conducted on measured emissions data from swine houses and manure storage facilities as well as concentration data in the vicinity of swine production facilities. Results from more than 80 studies were compiled with results from the 11 swine sites in the National Air Emiss...
متن کاملAmmonia Concentrations and Emissions in Livestock Production Facilities: Guidelines and Limits in the USA and UK
There is much information about the concentrations and emissions of ammonia in livestock production facilities in Europe and North America; examples of best and worst practice have been identified in terms of building design and environmental management. Numerically, cattle are the largest source of ammonia emissions, while the ammonia concentration in swine and poultry buildings is much higher...
متن کاملAmmonia and Greenhouse Gas Emissions of a Swine Breeding-Gestation-Farrowing Facility in the Midwestern USA
Aerial emissions from livestock production continue to be an area of concern for both the potential health and environmental impacts. However, information on gaseous, especially greenhouse gas (GHG) emissions for swine breeding/gestation and farrowing production facilities is meager. A 4300-sow breeding, gestation, and farrowing facility in Iowa was selected for extensive field monitoring. A Mo...
متن کاملVegetative Buffers for Swine Odor Mitigation - Wind Tunnel Evaluation of Air Flow Dynamics
Description: One of the most significant and persistent environmental concerns regarding swine production is odor transport from animal feeding operations and manure storage facilities. Odor constituents include ammonia, hydrogen sulfide, and various volatile organic compounds (VOCs), which may exist as individual gaseous compounds or adsorbed onto particulates (Zahn et al., 1997; Trabue et al....
متن کاملA Review of Ammonia Emissions from Confined Swine Feeding Operations
Ammonia emissions from swine feeding operations depend on the housing type; animal size, age, and type; manure management, storage, and treatment; climatic variables; and manure utilization or land application techniques. Techniques or methods for estimating or quantifying NH3 flux from a source to the atmosphere include nitrogen mass balance, micrometeorology, flux chambers, models, and emissi...
متن کامل