Finger doses for staff handling radiopharmaceuticals in nuclear medicine.
نویسندگان
چکیده
UNLABELLED Radiation doses to the fingers of occupational workers handling 99mTc-labeled compounds and 131I for diagnostic and therapeutic procedures in nuclear medicine were measured by thermoluminescence dosimetry. METHODS The doses were measured at the base of the ring finger and the index finger of both hands in 2 groups of workers. Group 1 (7 workers) handled 99mTc-labeled radiopharmaceuticals, and group 2 (6 workers) handled 131I for diagnosis and therapy. Radiation doses to the fingertips of 3 workers also were measured. Two were from group 1, and 1 was from group 2. RESULTS The doses to the base of the fingers for the radiopharmacy staff and physicians from group 1 were observed to be 17+/-7.5 (mean+/-SD) and 13.4+/-6.5 microSv/GBq, respectively. Similarly, the dose to the base of the fingers for the 3 physicians in group 2 was estimated to be 82.0+/-13.8 microSv/GBq. Finger doses for the technologists in both groups could not be calculated per unit of activity because they did not handle the radiopharmaceuticals directly. Their doses were reported in millisieverts that accumulated in 1 wk. The doses to the fingertips of the radiopharmacy worker and the physician in group 1 were 74.3+/-19.8 and 53.5+/-21.9 microSv/GBq, respectively. The dose to the fingertips of the physician in group 2 was 469.9+/-267 microSv/GBq. CONCLUSION The radiation doses to the fingers of nuclear medicine staff at our center were measured. The maximum expected annual dose to the extremities appeared to be less than the annual limit (500 mSv/y), except for a physician who handled large quantities of 131I for treatment. Because all of these workers are on rotation and do not constantly handle radioactivity throughout the year, the doses to the base of the fingers or the fingertips should not exceed the prescribed annual limit of 500 mSv.
منابع مشابه
The current status and future of theranostic Copper-64 radiopharmaceuticals
Copper-64 was produced in large scales and high specific activities in late 1990s’ using compact cyclotrons based by 64Ni(p,n)64Cu reaction and many radiopharmaceuticals developed since then by various groups based on interesting physicochemical and nuclear properties of the radionuclide. The unique emission of beta particles as well as positron particles offers a spectacu...
متن کاملStaff and patient absorbed doses due to diagnostic nuclear medicine procedures
Background: Annual patient effective dose equivalent can be considered as a quantitative physical parameter describing the activities performed in each nuclear medicine department. Annual staff dose equivalent could be also considered as a parameter describing the amount of radiation risk for performing the activities. We calculated the staff to patient dose equivalent ratio to be used as a phy...
متن کاملOccupational radiation dosimetry assessment using an automated infusion device for positron-emitting radiotracers.
UNLABELLED Handling and administration of radiopharmaceuticals are a key contributor to staff radiation dose. Shielded automated infusion devices potentially standardize and reduce radiation exposure during procedures. However, loading the devices adds incremental radiation exposure, which may mitigate dose savings. We measured radiation doses from the loading and use of an automated infusion d...
متن کاملThe Status of Stress Myocardial Perfusion Imaging Using 99mTc Pharmaceuticals in Japan: Results from a Nationwide Survey
Objective(s): To appropriately use one-day myocardial perfusion imaging (MPI) with 99mTc radiopharmaceuticals (i.e. to avoid shine-through artifacts), injection doses need to be optimized and dose ratios between the 1st and 2nd scans should be maintained at ≥ 3. However, the current state of practice in Japan is unclear. Thus, the aim of this study was to clarify the details of MPI protocols us...
متن کاملExternal radiation dose from patients received diagnostic doses of ²º¹Tl-Chloride and 99mTc-MIBI [Persian]
Patients receiving diagnostic doses of radiopharmaceuticals become a source of contamination and exposure for those who come in contact with them, such as nuclear medicine technologists, relatives and nurses. Therefore, the measurement of external radiation dose from these patients is necessary. In this study, the dose rates at distances of 10, 50 and 100cm from 70 patients who received d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 34 3 شماره
صفحات -
تاریخ انتشار 2006