Pulling geometry-induced errors in single molecule force spectroscopy measurements.
نویسندگان
چکیده
In AFM-based single molecule force spectroscopy, it is tacitly assumed that the pulling direction coincides with the end-to-end vector of the molecule fragment being stretched. By systematically varying the position of the attachment point on the substrate relative to the AFM tip, we investigate empirically and theoretically the effect of the pulling geometry on force-extension characteristics of double-stranded DNA. We find that increasing the pulling angle can significantly lower the force of the characteristic overstretching transition and increase the width of the plateau feature beyond the canonical 70%. These effects, when neglected, can adversely affect the interpretation of measured force-extension relationships. We quantitatively evaluate force and extension errors originating from this "pulling angle effect" and stress the need to correct the pulling geometry when stretching rigid molecules with an AFM.
منابع مشابه
Minimizing pulling geometry errors in atomic force microscope single molecule force spectroscopy.
In atomic force microscopy-based single molecule force spectroscopy (AFM-SMFS), it is assumed that the pulling angle is negligible and that the force applied to the molecule is equivalent to the force measured by the instrument. Recent studies, however, have indicated that the pulling geometry errors can drastically alter the measured force-extension relationship of molecules. Here we describe ...
متن کاملModel accounting for the effects of pulling-device stiffness in the analyses of single-molecule force measurements.
Single-molecule force spectroscopy provides a powerful approach for investigating molecular transitions along specific reaction coordinates. Here, we present a general analytical model for extracting the intrinsic rates and activation free energies from force measurements on single molecules that is applicable to a broad range of pulling speeds and device stiffnesses. This model relaxes existin...
متن کاملMonodisperse measurement of the biotin-streptavidin interaction strength in a well-defined pulling geometry
The widely used interaction of the homotetramer streptavidin with the small molecule biotin has been intensively studied by force spectroscopy and has become a model system for receptor ligand interaction. However, streptavidin's tetravalency results in diverse force propagation pathways through the different binding interfaces. This multiplicity gives rise to polydisperse force spectroscopy da...
متن کاملInfluence of pulling handles and device stiffness in single-molecule force spectroscopy.
In single-molecule force spectroscopy, individual molecules and complexes are often stretched by pulling devices via intervening molecular handles. Accurate interpretation of measurements from such experiments in terms of the underlying energy landscape, defined by activation barriers and intrinsic rates of transition, relies on our understanding, and proper theoretical treatment, of the effect...
متن کاملSingle-molecule pulling and the folding of donor-acceptor oligorotaxanes: phenomenology and interpretation.
The thermodynamic driving force in the folding of a class of oligorotaxanes is elucidated by means of molecular dynamics simulations of equilibrium isometric single-molecule force spectroscopy by atomic force microscopy experiments. The oligorotaxanes consist of cyclobis(paraquat-p-phenylene) rings threaded onto an oligomer of 1,5-dioxynaphthalenes linked by polyethers. The simulations are perf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biophysical journal
دوره 92 9 شماره
صفحات -
تاریخ انتشار 2007