Does the shape of the L5 vertebral body depend on the height of CT slices in the pedicle? Evaluation of the shape of the L5 vertebral body with a multicut CT scan.
نویسندگان
چکیده
STUDY DESIGN The shape of the L5 vertebral body was analyzed using a computerized tomography (CT) scan. OBJECTIVE The aim of this study is to determine if the vertebral L5 body shape varies depending on the height of the CT slices through the L5 pedicle. SUMMARY OF BACKGROUND DATA The morphometry of L5 has been studied to help the introduction of pedicular screws. The shape of the vertebral body has been seldom looked into, and the findings obtained show a triangular shape and hemispherical shape, supposedly owing to interpersonal variability. The hemisphere shape enables pedicular screws to be introduced nonconvergently, whereas the triangular shape enables pedicular screws to be introduced at a convergent angle but posing the risk of cortical perforation unless these guidelines are followed. METHODS Abdominal CT multicut with 64 crowns was performed in 101 consecutive patients with diverse indications. Width of CT slices was with a 1-mm reconstruction increase. We selected one axial slice that passed through the upper part of the pedicle and another one that passed through the lower part of the pedicle and compared next parameters in both cuts: pedicular cortical width, pedicular endostal width, pedicular angle, vertebral body length, vertebral body width, vertebral perimeter angles, and visual appearance of vertebral body shape. RESULTS We found statistical differences between all values except the anterior vertebral perimeter angle on comparing values of upper part with values of lower part and visual vertebral body shape was different in 93% of vertebrae. In the upper part the vertebral body is hemispherical whereas in the lower part it is triangular. CONCLUSION In most cases, the vertebral body shape is hemispherical in the upper part of the pedicle and triangular in the lower part of the pedicle. It means that in the lower part pedicular screws must be introduced at a more convergent angle than in the upper part if we do not want to break any cortical of the vertebral body.
منابع مشابه
False-positive FDG PET CT Scan in Vertebral Hemangioma
FDG PET CT scan is considered to be a sensitive tool to detect skeletal metastasis in known malignancies. However, it’s high sensitivity and low specificity may account for false positive diagnosis in cases of trauma, infection, inflammation and other benign conditions. Skeletal hemangioma is one of the common benign conditions which are typically ametabolic on FDG PET CT with no uptake on bone...
متن کاملEstimate bowtie filter shape in PET/CT scan with TLD
Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...
متن کاملstimate bowtie filter shape in PET/CT scan with TLD
Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...
متن کاملAssessment of corelation between spinal canal shape and spinal cord injury in thoracolumbar spine fractures
Traumatic spinal cord injury is one of the important causes of disability.in some of vertebral fractures,spinal canal is deformed and compromised.the relationship between the shape of the cervical canal and spinal cord hnjury has been proved but such a correlation for thoraculombar spine 50 patients with compromised canal(cases) and 50 oatients with intact canal were evaluated in the light of s...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Spine
دوره 33 1 شماره
صفحات -
تاریخ انتشار 2008