Pressure support compensation for inspiratory work due to endotracheal tubes and demand continuous positive airway pressure.

نویسندگان

  • J F Fiastro
  • M P Habib
  • S F Quan
چکیده

We evaluated the use of pressure support to compensate for the added inspiratory work of breathing due to the resistances of endotracheal tubes and a ventilator demand-valve system for continuous positive airway pressure (CPAP). A mechanical model was used to simulate spontaneous breathing at five respiratory rates through 7-mm, 8-mm, and 9-mm endotracheal tubes with and without a ventilator demand CPAP circuit. Added work was measured as the integral of the product of airway pressure and volume during inspiration. Additional work was a function of the tube's size, and each 1-mm decrease in the tube's diameter resulted in a 67 to 100 percent increase in work. Adding the ventilator CPAP circuit further increased work and was responsible for 30 to 50 percent of the total work resulting from a tube and CPAP circuit together. Pressure support was added to a level at which net work on the airway was zero, and a relationship between mean inspiratory flow (VT/TI) and the optimal level of pressure support was established for each endotracheal tube. The inspiratory work of breathing was then measured in normal subjects breathing with and without each endotracheal tube plus the demand CPAP circuit. Work per liter of minute ventilation due to the endotracheal tube and CPAP circuit was increased from 54 to 240 percent over levels measured while breathing through an open airway. For each endotracheal tube and VT/TI, a level of pressure support (range, 2 to 20 cm H2O) was found which eliminated added work in the spontaneously breathing subject. This level correlated well with that predicted from the data derived using the mechanical model. We conclude that when adjusting for an endotracheal tube's diameter and VT/TI, pressure support can be used to compensate for the added inspiratory work due to artificial airway resistances.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of automatic tube compensation in new-generation mechanical ventilators.

OBJECTIVE To compare performance of flow-adapted compensation of endotracheal tube resistance (automatic tube compensation, ATC) between the original ATC system and ATC systems incorporated in commercially available ventilators. DESIGN Bench study. SETTING University research laboratory. SUBJECTS The original ATC system, Dräger Evita 2 prototype, Dräger Evita 4, Puritan-Bennett 840. INT...

متن کامل

Does automatic tube compensation change metabolic parameters when added to pressure support mode during weaning?

Introduction Artificial airway increases work of breathing (WOB) during weaning [1] which is one of the reasons for weaning failure [2]. Pressure support ventilation (PSV) decreases WOB and oxygen expenditure by decreasing resistance caused by artificial airway. Because inspiratory flow changes with every breath during PSV, it can not constantly compansate the changes in resistance caused by ch...

متن کامل

Early Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial

Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...

متن کامل

Sudden Complete Versus Gradual Weaning from Nasal Continuous Positive Airway Pressure in Preterm Neonates: A Randomized Controlled Trial

Background: Continuous positive airway pressure (CPAP) is used as respiratory support in preterm neonates; however, the best weaning method has not yet been determined. In this study, we compared sudden complete and gradual weaning from nasal CPAP (NCPAP) in preterm newborns. Methods: This randomized controlled trial was conducted on 62 prete...

متن کامل

A Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome

Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 93 3  شماره 

صفحات  -

تاریخ انتشار 1988