Wavefront-optimized surface retreatments of refractive error following previous laser refractive surgery: a retrospective study.
نویسندگان
چکیده
BACKGROUND Retreatments are sometimes necessary to correct residual or induced refractive errors following refractive surgery. Many different combinations of primary treatment methods and retreatment techniques have been studied, however, few studies have investigated wavefront-optimized (WFO) technology for retreatment following primary refractive surgery. This study aimed to report the outcomes of WFO photorefractive keratectomy (PRK) retreatments of refractive error following previous laser refractive surgery with PRK, laser in situ keratomileusis (LASIK), or laser-assisted subepithelial keratectomy (LASEK). METHODS We reviewed records of patients who underwent WFO PRK retreatments using the Allegretto Wave Eye-Q 400 Hz Excimer Laser System (Alcon Surgical) between January 2008 and April 2011 at Walter Reed Army Medical Center and Madigan Army Medical Center. Outcomes were recorded in terms of uncorrected distance visual acuity (UDVA), manifest refraction spherical equivalent (MRSE), corrected distance visual acuity (CDVA), and complications at 1 month (M), 3 M, and 6 M post-op. RESULTS Seventy-eight patients (120 eyes) underwent WFO PRK retreatment during the study period. Primary surgery was surface ablation in 87 eyes (78 PRK, 9 LASEK) and LASIK in 33 eyes. The mean spherical equivalent before retreatment was -0.79 ± 0.94 D (-3.00 to 1.88 D). UDVA was ≥ 20/20 in 69 eyes (60.0 %) at 1 M, 54 eyes (71.1 %) at 3 M, and 27 eyes (73.0 %) at 6 M follow-up. MRSE was within ±0.50 D of emmetropia in 78 eyes (67.8 %) at 1 M, 59 eyes (77.6 %) at 3 M, and 25 eyes (67.6 %) at 6 M follow-up. CDVA was maintained within ±1 line of pre-op in 113 of 115 eyes (98.3 %) at 1 M, 74 of 76 eyes (97.4 %) at 3 M, and 37 eyes (100 %) at 6 M follow-up. CONCLUSION Although follow-up was limited beyond 3 M, WFO PRK retreatments in patients with residual refractive error may be a safe and effective procedure. Further studies are necessary to determine the long-term safety and stability of outcomes.
منابع مشابه
Wavefront-optimized versus wavefront-guided LASIK for myopic astigmatism with the ALLEGRETTO WAVE: three-month results of a prospective FDA trial.
PURPOSE To compare visual outcomes using the WaveLight ALLEGRETTO WAVE to administer either wavefront-optimized (standard LASIK) or wavefront-guided (custom LASIK) treatments in myopic eyes. METHODS In this prospective, open-label, multicenter study conducted in the United States, 374 eyes were randomized by alternating enrollment to receive either wavefront-optimized or wavefront-guided LASI...
متن کاملFlap lift and photorefractive keratectomy enhancements after primary laser in situ keratomileusis using a wavefront-guided ablation profile: Refractive and visual outcomes.
PURPOSE To analyze results of wavefront-guided laser vision correction retreatments performed either by lifting the original flap or by surface ablation over the flap. SETTING Optical Express, Glasgow, United Kingdom. DESIGN Retrospective case series. METHODS This retrospective study included patients grouped according to whether they had flap lift enhancement or photorefractive keratecto...
متن کاملRefractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy
Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...
متن کاملWavefront-guided laser in situ keratomileusis: early results in three eyes.
PURPOSE Wavefront optical aberrations induced by refractive corneal surgery correction of myopia are probably the reason for deterioration of visual performance in some eyes after surgery. Customized photoablation of the cornea to correct both the sphero-cylindrical refractive error as well as individual optical aberrations may improve postoperative visual acuity and visual performance. METHO...
متن کاملOptical ray tracing-guided myopic laser in situ keratomileusis: 1-year clinical outcomes
PURPOSE To compare the safety, efficacy, and predictability of laser in situ keratomileusis treatments at 1 year postprocedure using a novel geometric ray tracing algorithm with outcomes of treatments using wavefront-optimized, wavefront-guided, and topography-guided ablation profiles of an excimer laser (WaveLight GmbH, Erlangen, Germany; Alcon Laboratories, Fort Worth, TX, USA). SETTING Wel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Eye and vision
دوره 3 شماره
صفحات -
تاریخ انتشار 2016