Application and assessment of a membrane-based pCO2 sensor under field and laboratory conditions

نویسندگان

  • Zong-Pei Jiang
  • David J. Hydes
  • Sue E. Hartman
  • Mark C. Hartman
  • Jon M. Campbell
  • Bruce D. Johnson
  • Bryan Schofield
  • Daniela Turk
  • Douglas Wallace
  • William J. Burt
  • Richard Feely
چکیده

The principle, application, and assessment of the membrane-based ProOceanus CO2-Pro sensor for partial pressure of CO2 (pCO2) are presented. The performance of the sensor is evaluated extensively under field and laboratory conditions by comparing the sensor outputs with direct measurements from calibrated pCO2 measuring systems and the thermodynamic carbonate calculation of pCO2 from discrete samples. Under stable laboratory condition, the sensor agreed with a calibrated water-air equilibrator system at –3.0 ± 4.4 μatm during a 2-month intercomparison experiment. When applied in field deployments, the larger differences between measurements and the calculated pCO2 references (6.4 ± 12.3 μatm on a ship of opportunity and 8.7 ± 14.1 μatm on a mooring) are related not only to sensor error, but also to the uncertainties of the references and the comparison process, as well as changes in the working environments of the sensor. When corrected against references, the overall uncertainties of the sensor results are largely determined by those of the pCO2 references (± 2 and ± 8 μatm for direct measurements and calculated pCO2, respectively). Our study suggests accuracy of the sensor can be affected by temperature fluctuations of the detector optical cell and calibration error. These problems have been addressed in more recent models of the instrument through improving detector temperature control and through using more accurate standard gases. Another interesting result in our laboratory test is the unexpected change in alkalinity which results in significant underestimation in the pCO2 calculation as compared to the direct measurement (up to 90 μatm). *Corresponding author: E-mail: [email protected] Acknowledgments Full text appears at the end of the article. DOI 10.4319/lom.2014.12.264 Limnol. Oceanogr.: Methods 12, 2014, 264–280 © 2014, by the American Society of Limnology and Oceanography, Inc. LIMNOLOGY and OCEANOGRAPHY: METHODS

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation and Application of Al3+ - Sensor Based On (2Z) — Methyl 2 — ((z) (p-tolylimino) -3-Ethyl —4-0xothiazolidin —5— Ylidene Acetate in PVC Matrix

Al3+-Potentiometric sensor, based on (2Z) -methyl 2- ((z) (p-tolylimino)-3-ethyl -4-oxothiazolidin -5- ylidene) Acetate (MTEOY) as a neutral ionophore, was successfully developed for the detectionof Al3+ in aqueous solutions. The electrode responds to Al3+ ion with a sensitivity of 19.8 ± 0.1 mV/decade over the range 1.0 x 10-8- 1.0 x 10-1 mol LT' and in a pH range of 3.0-9.0. The electrodeshow...

متن کامل

Design and Evaluation of a Novel Bismuth Optical Sensor Using PC-ANN Application

The characterization of and construction of a new optical sensor based on the immobilization of Pyrocatechol Violet on a triacetylcellulose membrane was described to for the determination of bismuth (III) in real samples. The interaction between sensing membrane and bismuth (III) was caused at pH 3.80 in acetate buffer solution and the color changed from yellow to blue along with the appearance...

متن کامل

Biomedical Application of a Novel Nanostructured-based Electrochemical Platform for Therapeutic Monitoring of an Antiepileptic Drug; Gabapentin

Herein, gold nanoparticle had been successfully synthesized through a simple, inexpensive and clean electrochemical technique. Gold nanoparticles were directly deposited on the electrode surface using an electrochemical strategy. Then, the electrochemical deposition parameters (such as applied potential and deposition time) were optimized. 1.1 V and 250 s were applied as the optimal electrodepo...

متن کامل

Extended-Gate Field-Effect Transistor based Sensor for Detection of Hyoscine N-Butyl Bromide in its Pharmaceutical Formulation

A novel recognition method for selective determination of the hyoscine N-Butyl bromide (HBB), an antispasmodic agent for smooth muscles, was devised using extended gate field-effect transistor (EG-FET) as transducing unit. For this purpose a PVC membrane, containing hyoscine n-butyl-tetraphenyl borate ion-pair as recognition component, was coated on Ag/AgCl wire, which was connected to the exte...

متن کامل

Effect of Zinc and Boron Application on Wheat Mother Plant under Heat Stress on Cell Membrane Integrity of the Produced Seed and Physiological Quality of Seedling

Extended Abstract Introduction: Providing important and effective elements such as zinc and boron- especially in areas where the soil for some reason cannot meet the needs of the plant- will be a good solution to improve seed and seedling quality and nutrition, and community health status. A considerable part of the wheat producing regions in the country are faced with late season haet during ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014