Differences in measurement of lower limb alignment among different registration methods of navigation and radiographs in TKA using the OrthoPilot system.

نویسندگان

  • Seung-Suk Seo
  • Jin-Hyeok Seo
  • Myung-Whan Sohn
  • Yoon-Jun Kim
چکیده

The purposes of this study were (1) to compare lower limb alignment measurements between radiographs and computer-assisted surgery and (2) to evaluate the discrepancy in lower limb alignment between computer-assisted surgery with a high tibial osteotomy protocol and computer-assisted surgery with a total knee arthroplasty (TKA) protocol in the same knee. Seventy-one TKAs were performed on patients with primary osteoarthritis using computer-assisted surgery. Preoperative lower limb alignment was measured using the mechanical axis during bipedal, weight-bearing, whole-leg anteroposterior radiography (measure 1). The intraoperative mechanical axis was measured with computer-assisted surgery according to the high tibial osteotomy protocol before joint exposure (measure 2). After changing the software and joint exposure, the intraoperative mechanical axis was measured with computer-assisted surgery according to TKA protocol (measure 3). After final TKA implantation, the lower limb mechanical axis was measured with computer-assisted surgery following the TKA protocol (measure 4). Postoperative lower limb alignment was measured using the mechanical axis on whole-leg standing anteroposterior radiographs (measure 5). The mechanical axis and median value from each group were compared. Factors affecting the mechanical axis measurement were also analyzed. The difference in the mechanical axis between measures 1 and 2, measures 1 and 3, and measures 2 and 3 was significant (P<.0001, <.0001, and =.0007, respectively). The difference between measures 4 and 5 was also significant (P<.0001). Factors affecting the mechanical axis measurement, such as age, height, weight, and range of motion, showed no correlation (R(2)=.07244 and adjusted R(2)=.01622). The pre- and postoperative radiological measurements of limb alignment using the mechanical axis were different from the intraoperative measurements with navigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differing prosthetic alignment and femoral component sizing between 2 computer-assisted CT-free navigation systems in TKA.

We adopted a new computed tomography (CT)-free navigation system and noticed that, compared with our previous experience using a different type of CT-free navigation system that led to oversized and extended femoral component implanted compared with the conventional implantation, the femoral components were similarly implanted to the conventional method. The purpose of our study was to compare ...

متن کامل

Using Accelerometer-Based Portable Navigation to Perform Accurate Total Knee Arthroplasty Bone Resection in Asian Patients.

Implant alignment is an important factor affecting clinical results associated with total knee arthroplasty (TKA). No report exists showing the utility of an accelerometer-based portable navigation system among patients with marked femoral bowing. The aim of this study was to evaluate the accuracy of a portable navigation system for implant alignment in Asian patients with marked femoral bowing...

متن کامل

Computed Tomographic measurement of distal femor rotation in Iranian population

  Background: Proper rotation of components in total knee arthroplasty (TKA) will largely affect the postoperative outcome. Ethnical variation may affect rotational profile. We aimed to evaluate distal femur rotation in Iranian population using transepicondylar axes.   Methods : From a total of 450 knee CT scans and via consecutive sampling, 150 qualified subjects with normal lower extremities ...

متن کامل

Integration Scheme for SINS/GPS System Based on Vertical Channel Decomposition and In-Motion Alignment

Accurate alignment and vertical channel instability play an important role in the strap-down inertial navigation system (SINS), especially in the case that precise navigation has to be achieved over long periods of time. Due to poor initialization as well as the cumulative errors of low-cost inertial measurement units (IMUs), initial alignment is not sufficient to achieve required navigation ac...

متن کامل

Reliable Alignment in Total Knee Arthroplasty by the Use of an iPod-Based Navigation System

Axial alignment is one of the main objectives in total knee arthroplasty (TKA). Computer-assisted surgery (CAS) is more accurate regarding limb alignment reconstruction compared to the conventional technique. The aim of this study was to analyse the precision of the innovative navigation system DASH® by Brainlab and to evaluate the reliability of intraoperatively acquired data. A retrospective ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 10 Suppl  شماره 

صفحات  -

تاریخ انتشار 2012