Photometric Calibration for Automated Multispectral Imaging of Biological Samples
نویسندگان
چکیده
Over the past decade, there have been significant developments in the mechanisms for examination of biological and material samples. These developments exploit techniques in light microscopy to elucidate specific parts of cells and tissues, as well as inorganic particles. Sensor technology has progressed as well and modern charge-coupled devices (CCD) cameras are capable of achieving high spatial resolution and high sensitivity measurements of signals in the optical microscope. In this paper, we present a methodology for achieving photometric calibration of an automated multispectral imaging system targeted towards examination of biological samples. By acquiring spatial and spectral data simultaneously, multispectral imaging allows one to exploit physical connections between a particle’s morphology and its characteristic response to the optical spectrum. In composite biological material, the interpretation of the spectra is a complicated problem. This is because any light source and CCD camera used for data acquisition does not have a uniform illumination spectra and quantum efficiency, respectively, across the emitted light spectra. Fixed gain or exposure setting for a camera across all wavelengths does not allow efficient decoupling of the spectral signature of the biological particle from that of the camera’s imaging efficiency. To balance the spectral response across individual wavelengths, our method modulates the exposure duration for the CCD camera during image acquisition. We present an image similarity based method to calibrate the system. Five different distance metrics are compared and results presented by validating our approach by imaging particles in commercial blood standards. Photometric Calibration, Multispectral Imaging, Light Microscopy
منابع مشابه
Photometric calibration for quantitative spectral microscopy under transmitted illumination.
Over the past decade, there have been significant developments in the mechanisms for examination of biological and material samples. These developments exploit techniques in light microscopy to elucidate specific parts of cells and tissues, as well as inorganic particles. In recent years, spectral microscopy has become more prevalent for characterization of samples. Simultaneously, sensor techn...
متن کاملCorrecting cross-media instrument metamerism for reflectance estimation in multispectral imaging.
In multispectral imaging, the color accuracy of spectral reflectance estimation degrades significantly if the medium of test samples is different from that of calibration samples. This occurs mainly for two reasons, i.e., the different characteristics of spectral reflectances and the different measurement principles between an imaging system and a spectrophotometer. In this paper, this problem ...
متن کاملSpectral Separation of Quantum Dots within Tissue Equivalent Phantom Using Linear Unmixing Methods in Multispectral Fluorescence Reflectance Imaging
Introduction Non-invasive Fluorescent Reflectance Imaging (FRI) is used for accessing physiological and molecular processes in biological media. The aim of this article is to separate the overlapping emission spectra of quantum dots within tissue-equivalent phantom using SVD, Jacobi SVD, and NMF methods in the FRI mode. Materials and Methods In this article, a tissue-like phantom and an optical...
متن کاملDistinguishing modes of cell death using the ImageStream multispectral imaging flow cytometer.
BACKGROUND Here we demonstrate the ability of the ImageStream 100 Multispectral Imaging Cytometer to discriminate between live, necrotic, and early and late apoptotic cells, using unique combinations of photometric and morphometric features. METHODS Live, necrotic, and early and late apoptotic cells were prepared and analyzed by immunofluorescence microscopy, conventional flow cytometry, and ...
متن کاملDifferential Analysis of Peripherial Blood Leukocytes using ImageStream® Multispectral Imaging
automated clinical instruments that correlate cell volume and impedance (Coulter principle) with other measures such as light scatter and patterns of cellular staining. Evaluations using automated clinical instruments can accurately analyze and report on many samples per hour. The principal limitation of the automated approach is its difficulty in handling samples with atypical profiles. Such s...