Analysis of radiation doses incurred during diagnostic cerebral angiography after the implementation of dose reduction strategies.

نویسندگان

  • Tanja Schneider
  • Emily Wyse
  • Monica S Pearl
چکیده

BACKGROUND One goal of increasing awareness of radiation dose is to encourage personal and technical modifications in order to reduce the radiation exposure of patients and staff. OBJECTIVE To analyze the radiation doses incurred during diagnostic cerebral angiography and the angiographic techniques practiced over a 4-year period, in order to demonstrate the effectiveness of implementing radiation dose reduction strategies. METHODS A retrospective review of the first 50 consecutive adult and pediatric patients undergoing diagnostic cerebral angiography each year from 2010 to 2013 was performed. Angiograms and procedure examination protocols were reviewed for patient age, gender, diagnosis, angiography techniques, fluoroscopy time, reference point air kerma (Ka,r in mGy), and kerma-area product (PKA in μGym2). RESULTS From January 2010 to June 2013, a total of 231 diagnostic cerebral angiograms were reviewed (200 adults, 31 children). Adult patients were aged from 19 to 94 years and included 77 men and 123 women. Pediatric patients were aged from 2 to 18 years and comprised 11 boys and 20 girls. Median Ka,r and PKA significantly decreased from 2010 to 2013 in adults (1867 mGy; 21 231 µGym2 vs 653 mGy; 7860 µGym2) and children (644 mGy; 6495 µGym2 vs138 mGy; 1465 µGym2), (p<0.001). CONCLUSIONS Increased awareness and implementation of dose reduction strategies resulted in decreased radiation doses for diagnostic cerebral angiography both in adult and pediatric patients. The use of lower and variable digital subtraction angiography frame rates and tailored examinations contributed significantly to the reduced radiation doses observed during diagnostic cerebral angiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the annual effective dose to Cath Lab staff in the Afshar Hospital, Yazd and suggesting the radiation protection strategies to better management of occupational dose

Introduction Due to the increasing use of angiography procedures and the higher risk of deterministic and stochastic effects for radiation workers of these sections than other radiological procedures, radiation safety is very important in angiography staff. So, this study aimed to obtain the effective dose of angiography staff and compare them with the standard dose limit and finally outline th...

متن کامل

حفاظت پرتویی بیماران در سی تی آنژیوگرافی قلب

Introduction: Cardiac CT (Computed Tomography) angiography applies as a pre-exam method for evaluating the patients with medical problems in their cardiac arteries. Due to the high delivered dose in this imaging method, dose reduction techniques and imaging strategies that serve the images quality with minimum patient dose are the subjects for investigation and research studies. This study will...

متن کامل

Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz

Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...

متن کامل

Breast Radiation Protection in Coronary Angiography

Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...

متن کامل

Evaluation of cancer risk of the patients undergoing coronary angiography in Yazd, Iran

Background: Coronary angiography is a commonly performed diagnostic procedure with life saving benefits for the patient. However, this procedure involves relatively high radiation dose. The purpose of this study was to determine the average effective dose of patients undergoing coronary angiography and to estimate the associated radiation risk in terms of fatal malignancy. Materials an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurointerventional surgery

دوره 9 4  شماره 

صفحات  -

تاریخ انتشار 2017