Partial Discharge Measurement under an Oscillating Switching Impulse: A Potential Supplement to the Conventional Insulation Examination in the Field
نویسندگان
چکیده
Partial discharge (PD) detection under oscillating switching impulse (OSI) voltage was performed on three types of insulation defects, including a protrusion on a conductor, a particle on an insulator surface, and a void in an insulator, which are three kinds of the common potential insulation hazards in gas insulated power apparatus. Experiment indicated that the PD sequences under OSI were composed of various combinations of the single pulse, the multiple pulses, and the reverse polarity pulse. The difference between the PD inception voltage (PDIV) and the breakdown voltage (BDV) under OSI voltage was greater than that under alternating current (AC) voltage in some cases, which can provide a more sufficient margin below the BDV for PD diagnosis. The OSI voltage also showed a better performance for exciting PDs with detectable magnitudes from small-scale defects, of which the AC voltage was incapable under our test conditions. The different PD activities with different interfaces under an impulse and a slowly varying voltage were speculated to be associated with the gradient of the background electric field and the space-charge mobility.
منابع مشابه
Analysis and Diagnosis of Partial Discharge of Power Capacitors Using Extension Neural Network Algorithm and Synchronous Detection Based Chaos Theory
Power capacitors are important equipment of the power systems that are being operated in high voltage levels at high temperatures for long periods. As time goes on, their insulation fracture rate increases, and partial discharge is the most important cause of their fracture. Therefore, fast and accurate methods have great importance to accurately diagnosis the partial discharge. Conventional me...
متن کاملDetection of Partial Discharges in Power Transformers using UHF PD Measurements and Acoustic Measurements
For examination and diagnostics of the insulation quality of high voltage devices the measurement of partial discharge (PD) is accomplished. The conventional PD measurement according to IEC60270 is in some situations not sensitive enough because of the high interference level in field. The development of an unconventional measuring method using electromagnetic probes is presented. These probes ...
متن کاملSelf-Adaptive Morphological Filter for Noise Reduction of Partial Discharge Signals
Partial Discharge assessment in the insulation of high voltage equipment is one of the most popular approaches for prevention of the insulation breakdown. In the procedure of thisassessment, noise reduction of partial discharge signals to get the original PD signal for accurate evaluation is inevitable. This denoising process shall be carried out such a way that the main features of the p...
متن کاملElectric Insulation Detection Method for High-voltage Insulators
The principle of partial discharge detection is that through partial bridged discharge under high voltage electric field, it detects the inner air-filled cavity of high-voltage insulators. And it is a nondestructive detection method based on discharge magnitude to judge the insulation quality. The detecting system that adopts the partial discharge detection is more rigorous than testing system ...
متن کاملSensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation
Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -