SQUID-detected microtesla MRI in the presence of metal.

نویسندگان

  • Michael Mössle
  • Song-I Han
  • Whittier R Myers
  • Seung-Kyun Lee
  • Nathan Kelso
  • Michael Hatridge
  • Alexander Pines
  • John Clarke
چکیده

In magnetic resonance imaging performed at fields of 1 T and above, the presence of a metal insert can distort the image because of susceptibility differences within the sample and modification of the radiofrequency fields by screening currents. Furthermore, it is not feasible to perform nuclear magnetic resonance (NMR) spectroscopy or acquire a magnetic resonance image if the sample is enclosed in a metal container. Both problems can be overcome by substantially lowering the NMR frequency. Using a microtesla imaging system operating at 2.8 kHz, with a superconducting quantum interference device as the signal detector, we have obtained distortion-free images of a phantom containing a titanium bar and three-dimensional images of an object enclosed in an aluminum can; in both cases high-field images are inaccessible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microtesla MRI of the human brain combined with MEG.

One of the challenges in functional brain imaging is integration of complementary imaging modalities, such as magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI). MEG, which uses highly sensitive superconducting quantum interference devices (SQUIDs) to directly measure magnetic fields of neuronal currents, cannot be combined with conventional high-field MRI in a single...

متن کامل

Microtesla MRI with dynamic nuclear polarization.

Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by superconducting quantum interference device (SQUID) sensors to enable in vivo MRI at microtesla-range magnetic fields similar in strength to the Earth magnetic field. Despite significant advances in recent years, the potential of microtesla...

متن کامل

SQUID-detected magnetic resonance imaging in microtesla fields.

The use of very low noise magnetometers based on Superconducting QUantum Interference Devices (SQUIDs) enables nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) in microtesla magnetic fields. An untuned superconducting flux transformer coupled to a SQUID achieves a magnetic field noise of 10(-15) T Hz(-1/2). The frequency-independent response of this magnetometer combined wi...

متن کامل

Microtesla MRI with a superconducting quantum interference device.

MRI scanners enable fast, noninvasive, and high-resolution imaging of organs and soft tissue. The images are reconstructed from NMR signals generated by nuclear spins that precess in a static magnetic field B0 in the presence of magnetic field gradients. Most clinical MRI scanners operate at a magnetic field B0 = 1.5 T, corresponding to a proton resonance frequency of 64 MHz. Because these syst...

متن کامل

Multi-sensor system for simultaneous ultra-low-field MRI and MEG

Magnetoencephalography (MEG) and magnetic resonance imaging at ultra-low fields (ULF MRI) are two methods based on the ability of SQUID (superconducting quantum interference device) sensors to detect femtotesla magnetic fields. Combination of these methods will allow simultaneous functional (MEG) and structural (ULF MRI) imaging of the human brain. In this paper, we report the first implementat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 179 1  شماره 

صفحات  -

تاریخ انتشار 2006