The medial periosteal hinge, a key structure in fractures of the proximal humerus: a biomechanical cadaver study of its mechanical properties.
نویسندگان
چکیده
The medial periosteal hinge plays a key role in fractures of the head of the humerus, offering mechanical support during and after reduction and maintaining perfusion of the head by the vessels in the posteromedial periosteum. We have investigated the biomechanical properties of the medial periosteum in fractures of the proximal humerus using a standard model in 20 fresh-frozen cadaver specimens comparable in age, gender and bone mineral density. After creating the fracture, we displaced the humeral head medial or lateral to the shaft with controlled force until complete disruption of the posteromedial periosteum was recorded. As the quality of periosteum might be affected by age and bone quality, the results were correlated with the age and the local bone mineral density of the specimens measured with quantitative CT. Periosteal rupture started at a mean displacement of 2.96 mm (SD 2.92) with a mean load of 100.9 N (SD 47.1). The mean maximum load of 111.4 N (SD 42.5) was reached at a mean displacement of 4.9 mm (SD 4.2). The periosteum was completely ruptured at a mean displacement of 34.4 mm (SD 11.1). There was no significant difference in the mean distance to complete rupture for medial (mean 35.8 mm (SD 13.8)) or lateral (mean 33.0 mm (SD 8.2)) displacement (p = 0.589). The mean bone mineral density was 0.111 g/cm(3) (SD 0.035). A statistically significant but low correlation between bone mineral density and the maximum load uptake (r = 0.475, p = 0.034) was observed. This study showed that the posteromedial hinge is a mechanical structure capable of providing support for percutaneous reduction and stabilisation of a fracture by ligamentotaxis. Periosteal rupture started at a mean of about 3 mm and was completed by a mean displacement of just under 35 mm. The microvascular situation of the rupturing periosteum cannot be investigated with the current model.
منابع مشابه
The Mechanical Benefit of Medial Support Screws in Locking Plating of Proximal Humerus Fractures
BACKGROUND The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs) in the locking proximal humeral plate for treating proximal humerus fractures. METHODS Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal hume...
متن کاملA scoping review of biomechanical testing for proximal humerus fracture implants
BACKGROUND Fixation failure is a relatively common sequela of surgical management of proximal humerus fractures (PHF). The purpose of this study is to understand the current state of the literature with regard to the biomechanical testing of proximal humerus fracture implants. METHODS A scoping review of the proximal humerus fracture literature was performed, and studies testing the mechanica...
متن کاملThe radial nerve danger zone: A cadaver study
Distal humerus fractures are uncommon, comprising 2% of all fractures and a third of all humerus fractures. Open fractures, comminuted fractures and fracture dislocation of the elbow are often accompanied by severe soft tissue damage. External fixation of the humerus is indicated when severe soft tissue damage or the presence of infection warrants initial alternative immobilisation of the fract...
متن کاملAxillary Artery Injury Associated with Proximal Humerus Fracture: A Report of 6 Cases
Proximal humerus fractures are common, but associated injury of the axillary artery is uncommon. The majority of published blunt traumatic axillary artery injuries are associated with anterior glenohumeral dislocation; a few are associated with isolated proximal humerus fractures or fracture-dislocation. Experience within our institution demonstrates that axillary artery injury is often unreco...
متن کاملApplication of Additional Medial Plate in Treatment of Proximal Humeral Fractures With Unstable Medial Column
The purpose of this study was to use finite element analysis to compare the biomechanical characteristics after lateral locking plate (LLP) or LLP with a medial anatomical locking plate (LLP-MLP) fixation of proximal humeral fractures with an unstable medial column.First, a 3-dimensional, finite element analysis model was developed. Next, LLP and LLP-MLP implants were instrumented into the prox...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 91 7 شماره
صفحات -
تاریخ انتشار 2009