Dorsal nail plate versus percutaneous k-wire fixation in the treatment of displaced distal radius fractures.
نویسندگان
چکیده
Distal radius fractures are the most common fractures in the elderly, yet the treatment is controversial and still debated in the literature. Twenty four patients aged older than sixty with distal radial fractures were treated by dorsal nail plate. We compared them with twenty four similar matched patients treated by percutaneous Kirschner wiring surgical method. The patients were operated on by a surgeon experienced in carrying out hand surgery. The purpose of this retrospective review was to compare the clinical and radiological outcomes in elderly patients with displaced distal radial fractures who were treated with either the dorsal nail plate or percutaneous Kirschner wiring surgical procedures. Both groups had high union rates and low complication rates for the treatment of displaced distal radius fractures in elderly patients. However, better functional results can be expected in dorsal nail plate.
منابع مشابه
Dorsal nail plate fixation of distal radius fractures.
Intramedullary fixation of distal radius fractures is an emerging concept. The Dorsal Nail Plate is a new device that links a specifically designed stem to a small distal plate; bone fixation is supported by fixed-angle screws. The device is inserted dorsally using a minimally invasive technique ; its indications are unstable dorsally displaced extra-articular or simple articular distal radius ...
متن کاملPercutaneous pinning versus pin-in-plaster for treatment of distal radius fractures
Background: Distal radius fractures constitute 17% of all fractures and 75% of forearm fractures in adults. Due to the vital role of the hands in a wide range of daily tasks, quick recovery and fewer complications for the patients are important. The purpose of this study was to compare the two common treatments of distal radius fractures namely, percutaneous pinning and pin-in-plaster. Methods...
متن کاملDorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial.
INTRODUCTION Fractures of the distal radius are very common and mainly occur in the elderly. There has been an increasing use of locked volar plate fixations which report satisfactory results. However, some authors advocate the use of nail fixation. HYPOTHESIS The aim of this study is to compare dorsal nail plate versus locked volar plate fixation in the treatment of distal radius fractures w...
متن کاملPercutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial
OBJECTIVES To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. DESIGN A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. SETTING 18 trauma centres in the United Kingdom. PARTICIPANTS 461 adults with a dorsally displaced ...
متن کاملVolar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
Objective: The superiority of volar locking plate fixation and K-wire fixation on treatment of distal radius fractures was controversial. Thus, we performed a meta-analysis to compare the efficacy of volar locking plate and K-wires for distal radius fracture. Methods: We searched Embase, Medline and PubMed for randomized controlled trials which compare the effects of volar locking plate and K-w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta orthopaedica Belgica
دوره 81 1 شماره