Geometrical differences in gross target volumes between 3DCT and 4DCT imaging in radiotherapy for non-small-cell lung cancer
نویسندگان
چکیده
The aim of this study was to explore the characteristic of 3DCT scanning phases and estimate the comparative amount of respiration motion information included in 3DCT and 4DCT by comparing the volumetric and positional difference between the volumes from 3DCT and 4DCT for the radiotherapy of non-small-cell lung cancer (NSCLC). A total of 28 patients with NSCLC sequentially underwent 3DCT and 4DCT simulation scans of the thorax during free breathing. The 4DCT images with respiratory signal data were reconstructed and sorted into 10 phases throughout a respiratory cycle. GTV-3D from 3DCT, GTV-0%, GTV-20%, GTV-50% and GTV-70% from end-inspiration, mid-expiration, end-expiration and mid-inspiration of 4DCT, and the internal GTV (IGTV-10) from the fused phase of 4DCT were delineated based on the 50% phase image, respectively. The differences in the position, size, matching index (MI) and degree of inclusion (DI) for different volumes were evaluated. The variation in the centroid shifts of GTV-0% and GTV-3D, GTV-20% and GTV-3D, GTV-50% and GTV-3D, and GTV-90% and GTV-3D in the 3D direction was not significant (P = 0.990). The size ratios of GTV-0%, GTV-20%, GTV-50%, GTV-70% and IGTV-10 to GTV-3D were 0.94 ± 0.18, 0.95 ± 0.18, 0.98 ± 0.15, 1.00 ± 0.18 and 1.60 ± 0.55, respectively. DIs of GTV-3D in IGTV-10, and IGTV-10 in GTV-3D were 0.88 ± 0.14 and 0.59 ± 0.16 (P < 0.001). The 3DCT scanning phases are irregular. The CTV-to-ITV expansion should be isotropic when defining the ITV on the 3DCT. The internal GTV derived from 4DCT cannot completely include the GTV from 3DCT. An additional margin may be required when defining the ITV-based 4DCT.
منابع مشابه
Comparison of internal target volumes defined on 3-dimensional, 4-dimensonal, and cone-beam CT images of non-small-cell lung cancer
PURPOSE The purpose of this study was to compare the positional and volumetric differences of internal target volumes defined on three-dimensional computed tomography (3DCT), four-dimensional CT (4DCT), and cone-beam CT (CBCT) images of non-small-cell lung cancer (NSCLC). MATERIALS AND METHODS Thirty-one patients with NSCLC sequentially underwent 3DCT and 4DCT simulation scans of the thorax d...
متن کاملDosimetric study of a respiratory gating technique based on four-dimensional computed tomography in non-small-cell lung cancer
This study sought to compare the differences in target volumes and dose distributions to the targets and organs at risk (OARs) between a four-dimensional computed tomography (4DCT)-based respiratory-gated intensity-modulated radiation therapy (IMRT) plan (PlanEOE) and a three-dimensional CT (3DCT)-based IMRT plan (Plan3D) in patients with non-small-cell lung cancer (NSCLC). For 17 patients with...
متن کاملComparison of primary target volumes delineated on four-dimensional CT and 18 F-FDG PET/CT of non-small-cell lung cancer
BACKGROUND To determine the optimal threshold of 18 F-fluorodexyglucose (18 F-FDG) positron emission tomography CT (PET/CT) images that generates the best volumetric match to internal gross target volume (IGTV) based on four-dimensional CT (4DCT) images. METHODS Twenty patients with non-small cell lung cancer (NSCLC) underwent enhanced three-dimensional CT (3DCT) scan followed by enhanced 4DC...
متن کاملA Prospective Study Comparing Functional Imaging (18F-FDG PET) Versus Anatomical Imaging (Contrast Enhanced CT) in Dosimetric Planning for Non-small Cell Lung Cancer.
Objective(s): 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET-CT) is a well-used and established technique for lung cancer staging. Radiation therapy requires accurate target volume delineation, which is difficult in most cases due to coexisting atelectasis. The present study was performed to compare the 18F-FDG PET-CT with contrast enhanced computed tomogr...
متن کاملComparative evaluation of CT-based and PET/4DCT-based planning target volumes in the radiation of primary esophageal cancer.
PURPOSE To compare planning target volume (PTV) defined by PET combined with 4DCT to 3DCT and 4DCT. METHODS Eighteen (18/30) esophageal cancer patients who underwent 3DCT, 4DCT and (18)F-FDG PET-CT thoracic simulation with SUVmax≥2.0 of the primary volume were enrolled. CTV3D was formed on 3DCT by adding a margin of 30 mm in cranial-caudal direction and 5 mm in transversal direction. PTV3D wa...
متن کامل