Comparative study of a non-radiometric BACTEC system and a conventional blood culture system in a clinical microbiology laboratory.

نویسندگان

  • O F Yew
  • Y M Cheong
  • A R Zaidatul
  • N Thanaletchimy
چکیده

The BACTEC NR730 blood culture system is a commercially available system which utilizes infrared spectrophotometry to detect bacterial growth in broth media inoculated with the blood specimen. The objective of this study is to compare this system with the conventional system used in our laboratory. A total of 479 blood samples were collected from adult patients in the Klang TAR Hospital and inoculated simultaneously into the two systems. Clinically significant isolates were recovered from 59 (12.3%) specimens by one or both systems yielding a total of 65 isolates of which 41 isolates were recovered in both systems, 18 in BACTEC only and 6 in the conventional system (P < 0.01). Of the 40 (8.3%) blood cultures that were judged as contaminated, 2 were found in both systems, 12 in the BACTEC only and 26 in the conventional system. After 48 hours (day 2) the BACTEC system had recovered 93.2% of the total significant isolates while the conventional system recovered 61.7% only. Our results showed that the BACTEC system yielded more significant isolates in a shorter time and with a lower incidence of contamination as compared to the conventional system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of altered headspace atmosphere on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

The one-bottle Oxoid Signal blood culture system altered to provide a more aerobic bottle headspace was reassessed in a comparative study versus the two-bottle BACTEC radiometric system in 5,426 blood cultures. The BACTEC system detected more microorganisms (P less than 0.02), particularly anaerobes (P less than 0.05) and fungi (P less than 0.05).

متن کامل

Laboratory experience with radiometric detection of bacteremia with three culture media.

In two long-term studies, the BACTEC radiometric system for detection of bacteremia was evaluated with three culture media each: (i) BACTEC media 6A (for aerobes) and 7B (for anaerobes) plus a thioglycolate medium and (ii) BACTEC media 6A, 7B, and 8A (hypertonic). In study 1, clinically significant isolates were identified in 1,873 (13.9%) of 13,432 blood cultures with all three media. The thio...

متن کامل

Mycobacterial cross contamination during radiometric culturing.

Pseudobacteremias in blood cultures performed on the BACTEC radiometric blood culture system have been reported. We report three cases of cross contamination with Mycobacterium avium that occurred when mycobacteria were cultured with the BACTEC 460 TB system. Malfunction of the needle sterilization heating block was demonstrated.

متن کامل

Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia (M. P. Weinstein, S. Mirrett, and L. B. Reller, J. Clin. Microbiol. 26:962-964, 1988). To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive c...

متن کامل

Comparative evaluation of nonradiometric BACTEC and improved oxoid signal blood culture systems in a clinical laboratory.

The BACTEC NR660 blood culture system, which uses infrared spectroscopy to detect carbon dioxide generated by bacterial growth, was compared with the new medium formulation of the Oxoid Signal system. Two trials were conducted: a comparative study of 88 organisms in simulated blood cultures and a clinical trial of 3,321 paired patient blood culture samples. Both trials showed that overall the B...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Malaysian journal of pathology

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 1995