On-X versus St Jude Medical Regent mechanical aortic valve prostheses: early haemodynamics
نویسندگان
چکیده
OBJECTIVE We aimed to compare the early haemodynamic data of the On-X and St Jude Medical (SJM) Regent bileaflet mechanical prostheses in the aortic position. METHODS A retrospective study was performed using data collected prospectively for a national database. Thirty-three patients who had aortic On-X valve (On-X group) and 33 matched patients who had aortic SJM Regent valve (SJM group) were included. The intraoperative and early postoperative data were collected. The same echocardiographer reviewed all the echocardiograms and obtained the required parameters. RESULTS The peak gradient across the prosthetic valve was comparable between the two groups except for the labelled valve size of 25 mm for which the On-X group had lower peak gradient when compared with the SJM group. Mean gradients and effective orifice area indices of the two valve types within each valve size subgroup were comparable. CONCLUSIONS The current study confirms that in the early postoperative period, the two valve types had comparable haemodynamic outcomes.
منابع مشابه
A case of aortic valve replacement with St. Jude Medical Regent valve (first implant in Japan).
The St. Jude Medical (SJM) Regent valve was developed as a new mechanical valve by improving the conventional SJM valve. The effective orifice area is wider than that of Hemodynamic Plus (HP) series. The efficacy of the new valve has been reported in Europe and the United States. On October 26, 2004, we first performed aortic valve replacement (AVR) with the SJM Regent valve for aortic valve st...
متن کاملApplication of Regent mechanical valve in patients with small aortic annulus: 3-year follow-up
BACKGROUND Aortic valve replacement (AVR) with a small aortic annulus is always challenging for the cardiac surgeon. In this study, we sought to evaluate the midterm performance of implantation with a 17-mm or 19-mm St. Jude Medical Regent (SJM Regent) mechanical valve in retrospective consecutive cohort of patients with small aortic annulus (diameter ≤ 19 mm). METHODS From January 2008 to Ap...
متن کاملDoppler derived gradient of St. Jude mechanical prosthesis, early postoperative assessment.
OBJECTIVE To determine the doppler derived mean gradients of St Jude mechanical prosthesis in early postoperative period in patients undergoing valve replacement at a tertiary care cardiac centre. METHODS Medical records of 190 consecutive patients who underwent 233 mitral, aortic or dual (mitral and aortic) valve replacement by St Jude bileaflet mechanical prosthesis at Tabba Heart Institute...
متن کاملSeventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?
BACKGROUND The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) <indexed effective orifice area ≤ 0.85 cm(2)/m(2)) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. M...
متن کاملIntermittent stuck valve after aortic valve replacement with a mechanical valve
BACKGROUND Intermittent stuck valve after mechanical valve replacement surgery is a very rare and severe complication. CASE SUMMARY We present 1 case of a 53-year-old woman after aortic valve replacement for severe aortic valve stenosis combined with hypertrophy septum. She was diagnosed with intermittent stuck valve only 1 day after surgery by clinical symptoms, intraoperative transoesophage...
متن کامل