Iterative Method for Intrinsic Viscosity Measurements on Perpendicular Recording Media

نویسنده

  • Kim Le Phan
چکیده

In this paper, we introduce a new method that allows to directly measure the intrinsic viscosity ( ) for perpendicular media using a vibrating sample magnetometer. The measurement is carried out in a number of iterations. In each iteration, the behavior of applied field ( ) with time is gradually adjusted according to the change in the internal field ( ) calculated from the relaxation behavior measured in the previous iteration. Eventually, during the last iteration, from which the intrinsic viscosity can be extracted, is kept constant by appropriately changing .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Iterative Decoding for Perpendicular Magnetic Recording

An algorithm of improving the performance of iterative decoding on perpendicular magnetic recording is presented. This algorithm follows on the authors’ previous works on the parallel and serial concatenated turbo codes and low-density parity-check codes. The application of this algorithm with signalto-noise ratio mismatch technique shows promising results in the presence of media noise. We als...

متن کامل

Remanent magnetic measurements on perpendicular recording materials with compensation for demagnetizing fields

Existing techniques for characterization of longitudinal recording media using remanence measurements are extended to perpendicular media, in particular to Alumite, and correction for demagnetizing fields is taken into account. It is found that these techniques have limited value because of the sensitivity of the analysis to the correction factor used. Measurement of the recoil lines is investi...

متن کامل

Effect of Sweeteners on Viscosity and Particle Size of Dilute Guar Gum Solutions

The effects of some synthetic sweeteners on the rheological and physical properties of guar gum in dilute solutions were investigated.Measurements include the determination of intrinsic viscosity and the particle size, surface weighted mean [D3, 2], volume weighted mean [D4,3] and specificsurface area ofguar gum andsyntheticsweeteners mixtures. T...

متن کامل

Robustness of Per-Survivor Iterative Timing Recovery Against Pattern-Dependent Noise in Perpendicular Recording

Per-survivor iterative timing recovery was proposed by Kovintavewat, Barry, Erden, and Kurtas [1] to perform timing recovery, equalization, and errorcorrection decoding jointly. In this paper, we investigate the robustness of this scheme in the situation where the channel is dominated by media jitter noise. We apply the pattern-dependent noisepredictive (PDNP) technique to per-survivor iterativ...

متن کامل

On the relationship between magnetic viscosity and cgercivity of perpendicular media

The dependent and dc-demagnetization measurements were performed on two types of perpendicular thin film media, Co-Cr and Fe-alumite. From these the parameters for magnetic viscosity and irreversible susceptibility were derived. Their ratio, resulting in the fluctuation field, is shown to relate logarithmically to the coereivity. This so-called “Barbier plot for perpend$cular media” is found to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001