Monitoring microemboli during cardiopulmonary bypass with the EDAC quantifier.
نویسندگان
چکیده
Gaseous emboli may be introduced into the bypass circuit both from the surgical field and during perfusionist interventions. While circuits provide good protection against massive air embolism, they do not remove gaseous microemboli (GME) from the bypass circuit. The purpose of this preliminary study is to assess the incidence of GME during bypass surgery and determine if increased GME counts were associated with specific events during bypass surgery. In 30 cases divided between 15 coronary artery bypass grafts and 15 valve repairs, GME were counted and sizedt the three locations on the bypass circuit using the EDAC" Quantifier (Luna Innovations, Roanoke, VA). A mean of 45,276 GME were detected after the arterial line filter during these 30 cases, with significantly more detected (p = .04) post filter during valve cases (mean = 72,137 +/- 22,113) than coronary artery bypass graft cases (mean = 18,416 +/- 7831). GME detected post filter were significantly correlated in time with counts detected in the venous line (p < .001). Specific events associated with high counts included the initiation of cardiopulmonary bypass, heart manipulations, insertion and removal of clamps, and the administration of drugs. Global factors associated with increased counts post filter included higher venous line counts and higher post reservoir/bubble trap counts. The mean number of microemboli detected during bypass surgery was much higher than reported in other studies of emboli incidence, most likely due to the increased sensitivity of the EDAC Quantifier compared to other detection modalities. The results furthermore suggest the need for further study of the clinical significance of these microemboli and what practices may be used to reduce GME incidence. Increased in vitro testing of the air handling capability of different circuit designs, along with more clinical studies assessing best clinical practices for reducing GME activity, is recommended.
منابع مشابه
Vacuum-assisted venous drainage and gaseous microemboli in cardiopulmonary bypass.
When conventional gravity siphon venous drainage cannot achieve satisfactory venous drainage during minimally invasive cardiac and neonatal surgeries, assisted venous drainage techniques are needed to ensure adequate flow. One assisted venous drainage technique, vacuum-assisted venous drainage (VAVD), the aid of a vacuum in the venous reservoir, is now widely used to augment venous drainage dur...
متن کاملGaseous microemboli in a pediatric bypass circuit with an unprimed venous line: an in vitro study.
Miniaturizing cardiopulmonary bypass (CPB) circuits to reduce hemodilution and allogenic blood product administration is common in cardiac surgery. One major concern associated with smaller CPB circuits is a possible increase in gaseous microemboli (GME) sent to the cerebral vasculature, which is exacerbated by vacuum-assisted venous drainage (VAVD). The use of VAVD has increased with smaller v...
متن کاملArterial Limb Microemboli during Cardiopulmonary Bypass: Observations from a Congenital Cardiac Surgery Practice.
Gaseous microemboli (GME) are known to be delivered to the arterial circulation of patients during cardiopulmonary bypass (CPB). An increased number of GME delivered during adult CPB has been associated with brain injury and postoperative cognitive dysfunction. The GME load in children exposed to CPB and its consequences are not well characterized. We sought to establish a baseline of arterial ...
متن کاملMicroemboli in our bypass circuits: a contemporary audit.
Cardiopulmonary bypass (CPB) may introduce microemboli into the patient's arterial circulation. These may arise from the CPB circuit. Most relevant studies have been performed in vitro; there are relatively few clinical studies. We used the Emboli Detection and Classification quantifier (EDAC) (Luna Innovations, Roanoke, VA) in a prospective clinical audit of emboli in a contemporary CPB circui...
متن کاملClinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population.
The use of an arterial line filter (ALF) within the pediatric cardiopulmonary bypass (CPB) circuit is not a new concept. It has always presented the perfusionist with a circuit component that while valuable, increased prime volume. The purpose of this study was to evaluate the change in prime volume and emboli between a conventional oxygenator with separate ALF and a new generation oxygenator w...