The influence of end of day silicone hydrogel daily disposable contact lens fit on ocular comfort, physiology and lens wettability.
نویسندگان
چکیده
PURPOSE To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. METHODS Thirty-nine subjects (22.1±3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. RESULTS Lens fit assessments were not different between brands (P>0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12h (P<0.05), but remained stable from 12 to 16h (P>0.05). Movement-on-blink was unaffected by wear-time (F=0.403, P=0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r=-0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P>0.01). CONCLUSIONS Among the lenses tested, objective lens fit changed between 8h and 12h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit.
منابع مشابه
Factors in contact lens symptoms: evidence from a multistudy database.
PURPOSE This study aimed to examine the effects of demographic, lens performance, and ocular surface response measures on contact lens-related discomfort and dryness, using a large contact lens study database. METHODS A total of 4164 records were extracted from a database of 220 subjects participating in 46 silicone hydrogel contact lens studies. Subjects discontinued lens wear for 24 hours a...
متن کاملContinuing education CET
● Tear film assessment should be undertaken with minimal invasion of the structure – non-invasive techniques should be used whenever possible ● Assessment must be made both prior to and during contact lens wear. Tear film quality should be assessed both with the lens in situ and without the lens ● Use of the Tearscope in clinical practice allows a more detailed examination of the tears to be un...
متن کاملThe influence of corneoscleral topography on soft contact lens fit.
PURPOSE To evaluate the influence of peripheral ocular topography, as evaluated by optical coherence tomography (OCT), compared with traditional measures of corneal profile using keratometry and videokeratoscopy, on soft contact lens fit. METHODS Ocular surface topography was analyzed in 50 subjects aged 22.8 years (SD ±5.0) using videokeratoscopy (central keratometry, corneal height, and sha...
متن کاملIncidence of keratitis of varying severity among contact lens wearers.
AIM To determine the incidence of non-severe keratitis (NSK) and severe keratitis (SK) among wearers of current generation contact lenses. METHODS A 12 month, prospective, hospital based epidemiological study was conducted by examining all contact lens wearers presenting with a corneal infiltrate/ulcer to a hospital centre in Manchester. A clinical severity matrix was used to differentiate be...
متن کاملSilicone Hydrogels Materials for Contact Lens Applications
Silicone hydrogel (Si-Hy) materials combine the benefi ts of silicone or siloxane derivates in terms of oxygen permeability and mechanical properties with those of hydrogels in terms of wettability and hidrophilicity. Such properties are critical when it comes to the application at the ocular surface in the form of contact lenses (CL) to correct visual dysfunctions, as bandage mechanism or as d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Contact lens & anterior eye : the journal of the British Contact Lens Association
دوره 38 5 شماره
صفحات -
تاریخ انتشار 2015