Effect of a metal primer on the adhesive interface between composite and lingual brackets.

نویسندگان

  • Julio Pedrae Cal Neto
  • José de Albuquerque Calasans-Maia
  • Natalia Valli de Almeida
  • Helen Rohen
  • Maria Angélica Galvão Freire
چکیده

AIM To test the null hypothesis was that there is no difference in the shear strength of indirectly bonded lingual brackets with or without prior application of metal primer on their bases. MATERIALS AND METHODS Forty recently extracted human premolars were obtained and randomly divided into two groups of 20 each: group I (control), phosphoric acid and indirect bonding with Maximum Cure (Reliance Orthodontic Products, Itasca, IL, USA); and group II, application of metal primer (Metal Primer, Reliance Orthodontic Products) on bracket base prior to conditioning and indirect bonding. All products were used according to the manufacturer's instructions. A universal testing machine was used to apply a shear force directly onto the enamel- bracket interface at a speed of 1.0 mm/min. RESULTS Mean (SD) shear bond strength for group I was 12.87 (5.75) MPa and for the group II was 18.47 (8.48) MPa. The Student's t-test showed a significant difference (p = 0.0311) between the groups. The chi-square test for the adhesive remnant index (ARI) indicated that there was a significant difference (p = 0.2750). CONCLUSION The application of metal primer increased the adhesion of lingual brackets, and may be a promising procedure for clinical orthodontics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microleakage under Orthodontic Metal Brackets Bonded with Three Different Bonding Techniques with/without Thermocycling

Introduction: The aim of this study was to compare the microleakage of beneath the orthodontic brackets bonded with 3 different bonding techniques and evaluate the effect of thermocycling. Methods: One hundred and twenty premolars were randomly divided into 6 groups, received the following treatment: group 1: 37% phosphoric acid gel+Unite primer+Unite adhesive, group 2: 37% phosphoric acid gel+...

متن کامل

Effect of Saliva Contamination and sequencing time of curing the Transbond™ Plus Self Etching Primer on the Shear Bond Strength of Orthodontic Brackets

Abstract Background and aim: Over the years, improvments have been done to simplify clinical bonding procedure. One of these material is Transbond™ Plus Self Etching. The aim of this study was to evaluate the effect of saliva contamination and reusing Transbond™ Plus Self Etching Primer (SEP) on shear bond strength of orthodontic brackets. Materials and Methods: Fifty premolars divided into fiv...

متن کامل

بررسی آزمایشگاهی میزان ریزنشت براکت‌های ارتودنسی باند‌شده با کامپوزیت بیس متاکریلات و کامپوزیت بیس سایلوران

Background: One of the orthodontic treatment problems, which causes marginal gaps and microleakage between tooth and composite is microleakage of composite bonding of orthodontic brackets. The microleakage formation permitting the passage of bacteria and oral fluids, which may cause white spot lesions under the brackets surface area.This is a clinical problem during orthodontic treatment. Few s...

متن کامل

Evaluation of Diode laser (940 nm) irradiation effect on microleakage in class V composite restoration before and after adhesive application

Introduction: Nowadays, the main focus of dental studies is on adhesive dental materials; since clinical long-term success of bonded restorations depended more on marginal microleakage minimization. So, the aim of this study was Evaluation of Diode laser irradiation effect on microleakage in class V composite restoration before and after adhesive application. Materials and methods: In this in v...

متن کامل

مقایسه استحکام باند برشی براکت‌های فلزی باند شده با کامپوزیت بیس سایلوران و کامپوزیت بیس متاکریلات

  Background and Aims: Orthodontic bracket failure during treatment is a common problem. With the introduction of low shrinkage composites the question is that whether: this sufficient has coefficient bond strength for bonding bracket during orthodontic treatment. The aim of this study was to compare the shear bond strength (SBS) of silorane-based and metacrylate-based composites to metal brack...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2013