Op-brai140307 136..148
نویسندگان
چکیده
The pathophysiology of post-stroke fatigue is poorly understood although it is thought to be a consequence of central nervous system pathophysiology. In this study we investigate the relationship between corticomotor excitability and self-reported nonexercise related fatigue in chronic stroke population. Seventy first-time non-depressed stroke survivors (60.36 12.4 years, 20 females, 56.81 63 months post-stroke) with minimal motor and cognitive impairment were included in the cross-sectional observational study. Fatigue was measured using two validated questionnaires: Fatigue Severity Scale 7 and Neurological Fatigue Index – Stroke. Perception of effort was measured using a 0–10 numerical rating scale in an isometric biceps hold-task and was used as a secondary measure of fatigue. Neurophysiological measures of corticomotor excitability were performed using transcranial magnetic stimulation. Corticospinal excitability was quantified using resting and active motor thresholds and stimulusresponse curves of the first dorsal interosseous muscle. Intracortical M1 excitability was measured using paired pulse paradigms: short and long interval intracortical inhibition in the same hand muscle as above. Excitability of cortical and subcortical inputs that drive M1 output was measured in the biceps muscle using a modified twitch interpolation technique to provide an index of central activation failure. Stepwise regression was performed to determine the explanatory variables that significantly accounted for variance in the fatigue and perception scores. Resting motor threshold (R = 0.384; 95% confidence interval = 0.071; P = 0.036) accounted for 14.7% (R) of the variation in Fatigue Severity Scale 7. Central activation failure (R = 0.416; 95% confidence interval = 1.618; P = 0.003) accounted for 17.3% (R) of the variation in perceived effort score. Thus chronic stroke survivors with high fatigue exhibit high motor thresholds and those who perceive high effort have low excitability of inputs that drive motor cortex output. We suggest that low excitability of both corticospinal output and its facilitatory synaptic inputs from cortical and sub-cortical sites contribute to high levels of fatigue after stroke.
منابع مشابه
Transvenous versus open chest lead placement for resynchronization therapy in patients with heart failure: comparison of ventricular electromechanical synchronicity
BACKGROUND Transvenous lead placement is the standard approach for left ventricular (LV) pacing in cardiac resynchronization therapy (CRT), while the open chest access epicardial lead placement is currently the most frequently used second choice. Our study aimed to compare the ventricular electromechanical synchronicity in patients with heart failure after CRT with these two different LV pacing...
متن کاملPunctuated Equilibrium Models in Organizational Decision Making
8.1 Two Research Conundrums..................................................................................................134 8.1.1 Lindblom’s Theory of Administrative Incrementalism...........................................134 8.1.2 Wildavsky’s Theory of Budgetary Incrementalism.................................................135 8.1.3 The Diverse Meanings of Budgetary “Incrementalism”.......
متن کاملPostmenopausal women with osteoporosis and osteoarthritis show different microstructural characteristics of trabecular bone in proximal tibia using high-resolution magnetic resonance imaging at 3 tesla
BACKGROUND Osteoporosis (OP) and osteoarthritis (OA) are two common musculoskeletal disorders that affect the quality of life in aged people. An inverse relationship between OP and OA was proposed four decades ago. However, the difference in microstructure of the trabecular bone of these two disorders by high-resolution MRI (HR-MRI) has not been compared. The primary objective of the study is t...
متن کاملMapping air contaminants indoors using a prototype computed tomography system.
Single and multiple plumes of sulphur hexafluoride were measured and mapped using a prototype open-path Fourier transform infrared spectrometer (OP-FTIR)-computed tomography (CT) system in an indoor exposure chamber. The OP-FTIR-CT system accurately mapped the position of concentration peaks at different locations in the chamber, and estimated concentrations within a range of 4-50% when compare...
متن کاملLong-term follow-up of non-operated patients with symptomatic gallbladder stones: a retrospective study evaluating the role of Hepatobiliary scanning
BACKGROUND To assess hepatobiliary (HB) scans for predicting recurrent symptoms in nonoperated patients with mild or vague symptomatic gallstones. METHODS Data of 170 patients with symptomatic gallstone and who had not undergone cholecystectomy were retrospectively enrolled. These patients were divided into two groups according to whether or not operations were performed due to recurrent symp...
متن کامل