A simple technique for craniospinal radiotherapy in the supine position.

نویسندگان

  • Glenn Bauman
  • Eugene Wong
  • Kristina Trenka
  • Danielle Scott
چکیده

PURPOSE Craniospinal irradiation poses technical difficulties that may be addressed with the use of the newer technologies that have become available over the past decade. The use of CT simulation allows improved target localisation and beam geometry definition while significantly reducing the treatment simulation time. We have developed a CT-based technique for whole CNS irradiation in the supine position that uses fixed field parameters, asymmetric jaws for field matching and drastically reduces simulation and treatment times. METHODS The patient is CT scanned and treated in the supine position. The clinical target volume and relevant critical structures are outlined on a planning CT scan. Half beam blocked lateral fields with a collimator rotation are used to match the beam divergence from the superior border of the spinal field at the C2 vertebral body. The shielding for the cranial fields is generated automatically, and the dose distribution is calculated using a 3D treatment planning system. Fixed field parameters are used for the planning and treatment. The position of the isocenter of the spine field is always a fixed longitudinal distance from the isocenter of the brain fields. If multiple posterior fields are required, the isocenter of the second spine field is always a fixed longitudinal distance from that of the first and the gap between the fields is determined using virtual simulation and feathered during treatment using the asymmetric jaws of the linear accelerator. All treatment portals are filmed daily during the first week of treatment, and after each junction change thereafter. RESULTS AND CONCLUSION The supine position provides numerous advantages. Patients are more comfortable, the treatment position is more reproducible, and access to the airway is possible, if necessary, for patient sedation. The use of CT simulation decreases the simulation time, allows for increased planning accuracy, and enables the use of multimodality image registration, and 3D treatment planning. The use of asymmetric jaws allows for junction feathering without changing the patient setup or using a couch angle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

An image‐guided technique for planning and verification of supine craniospinal irradiation

We present a technique for planning and verification of craniospinal treatment with the patient in the supine position. Treatment delivery and verification is streamlined through the use of modern imaging techniques. Treatments use two lateral brain fields abutted to a single or pair of posterior spine fields. Treatment delivery is simplified by aligning all isocenters in the anterior-posterior...

متن کامل

Evaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy

Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...

متن کامل

Evaluation of incidence of intestinal complications during radiation therapy in two supine and prone positions in patients with rectal cancer

Introduction: Radiation therapy is one of the main treatments for rectal cancer. In three-dimensional conformal radiotherapy, exposure of healthy tissue around the tumor is unavoidable. The small intestine is the most important organ at risk of rectal cancer radiotherapy. Intestinal complications are a major factor limiting the dose radiotherapy for rectal cancer. The most com...

متن کامل

Method to plan, administer, and verify supine craniospinal irradiation

Craniospinal irradiation remains an important technique in the management of malignancies of the central nervous system. It is technically demanding, with potential for treatment field overlap or gaps to yield unacceptable dosimetric heterogeneity. A method to accurately simulate and verify the three-field junction is described. We use a comfortable supine position to minimize patient movement....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

دوره 80 3  شماره 

صفحات  -

تاریخ انتشار 2006