The Results of Self-Expandable Kissing Stents in Aortic Bifurcation

نویسندگان

  • Jae Young Moon
  • Hong Pil Hwang
  • Hyo Sung Kwak
  • Young Min Han
  • Hee Chul Yu
چکیده

PURPOSE Kissing stent reconstruction is a widely used technique for the management of aortoiliac occlusive disease involving the aortic bifurcation or proximal common iliac arteries. The purpose of this study was to evaluate the results of self-expandable kissing stents in the aortic bifurcation. MATERIALS AND METHODS We reviewed medical records of the patients treated with a kissing stent retrospectively from January 2007 to December 2012. The primary and secondary patencies were determined with Kaplan-Meier analysis, and Cox regression was used to determine the factors associated with patency. RESULTS A total of 21 patients were included, and all were male (median age 53±15 years, range 48-78 years). Major symptoms were claudication (n=16, 61.9%), rest pain (n=5, 23.8%) and gangrene (n=5, 23.8%). Tans-Atlantic Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC) II classification was A 2 (9.5%), B 5 (23.8%), C 7 (33.3%) and D 8 (38%). The mean follow-up was 40.7 months. Major complication occurred in only one case which consisted of distal limb ischemia by emboli. Six patients developed symptomatic restenosis or occlusion. There was no major amputation, but minor amputation occurred in 3 patients. There were 2 mortalities not associated with the procedure (lung cancer and intracranial hemorrhage). Primary patency was 89.6% at 1 year, 74.7% at 3 years and 64.0% at 5 years. Secondary patency was 94.1% at 1 year, 88.2% at 3 years and 68.6% at 5 years. No risk factors for restenosis or occlusion were identified. CONCLUSION Self-expandable kissing stents can be used successfully with comparable patency for endovascular treatment of symptomatic atherosclerotic occlusive lesions in the aortic bifurcation area.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometrical consequences of kissing stents and the Covered Endovascular Reconstruction of the Aortic Bifurcation configuration in an in vitro model for endovascular reconstruction of aortic bifurcation.

OBJECTIVE Kissing stents (KS) are commonly used to treat aortoiliac occlusive disease, but patency results are often lower than those of isolated stents. The Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) technique was recently introduced to reconstruct the aortic bifurcation in a more anatomical and physiological fashion. The aim of this study is to compare the geometric...

متن کامل

Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent

Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...

متن کامل

In vivo geometry of the kissing stent and covered endovascular reconstruction of the aortic bifurcation configurations in aortoiliac occlusive disease

Objectives Various configurations of kissing stent (KS) configurations exist and patency rates vary. In response the covered endovascular reconstruction of the aortic bifurcation configuration was designed to minimize mismatch and improve outcome. The aim of the current study is to compare geometrical mismatch of kissing stent with the covered endovascular reconstruction of the aortic bifurcati...

متن کامل

Stent-supported reconstruction of the aortoiliac bifurcation with the kissing balloon technique.

BACKGROUND Bilateral iliac artery obstructions involving the aortic bifurcation or high-grade stenosis of the abdominal aorta are not usually considered an indication for percutaneous treatment. The purpose of the present study was to evaluate the initial and long-term results of primary stent implantation for reconstruction of the aortic bifurcation. METHODS AND RESULTS In 48 patients with o...

متن کامل

Disintegration of a Balloon-Expandable Stent in the Iliac Artery Upon Delivery

Although there are still some controversies on the choice of ideal stent as well as balloon-expandable versus self-expanding stents for aorto-iliac disease; iliac stenting is widely accepted procedure for focal atherosclerotic iliac artery stenosis. Herein, we present an unusual unilateral iliac stenting complication caused by disintegration struts of balloon-expandable stent which was successf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 31  شماره 

صفحات  -

تاریخ انتشار 2015