Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force-Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain.

نویسندگان

  • Milad El Haddad
  • Philippe Taghji
  • Thomas Phlips
  • Michael Wolf
  • Anthony Demolder
  • Rajin Choudhury
  • Sébastien Knecht
  • Yves Vandekerckhove
  • Rene Tavernier
  • Hiroshi Nakagawa
  • Mattias Duytschaever
چکیده

BACKGROUND Pulmonary vein reconnection (PVR) still determines recurrences of atrial fibrillation after contact force (CF)-guided pulmonary vein isolation. We studied whether acute PVR (adenosine and waiting time) and late PVR (at repeat) are explained by incomplete transmurality and contiguity within the deployed radiofrequency circle. METHODS AND RESULTS We analyzed 42 CF-guided ipsilateral pulmonary vein isolation procedures. For each radiofrequency tag within the circle, we collected data reflecting lesion depth (time of application, power, impedance drop [Δ-Imp], CF, force-time integral [FTI], and ablation index [AI]) and contiguity (automated interlesion distance [ILD]). Ablation line contiguity index (ALCI) was developed as a novel automated algorithm combining depth and contiguity into one single criterion. Each circle was subdivided into 10 segments. For each segment, we determined its weakest link by annotating timemin, powermin, Δ-Impmin, CFmin, FTImin, AImin, ILDmax, and ALCImin. Compared with segments without PVR (n=758), PVR segments (n=44) were characterized by lower Δ-Impmin (4.8 versus 7.4 Ω), CFmin (8.5 versus 11.8 g), FTImin (351 versus 473 gs), AImin (367 versus 408 arbitrary unit [au]), and higher ILDmax (6.8 versus 5.5 mm). ALCImin was significantly lower in segments with PVR (74% versus 104%; P<0.001) and was associated with the highest accuracy to predict durable segments (area under the curve=0.73). CONCLUSIONS In CF-guided pulmonary vein isolation, PVR is explained by lack of both lesion depth and contiguity within the deployed radiofrequency circle. ALCI, a novel measure combing contiguity and depth, is the most accurate predictor for durable segments. By avoiding weak links in the ablation chain, ALCI-guided ablation is expected to improve success rate of point-by-point radiofrequency ablation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

What Is the Best Age for Diagnostic Prediction of Pediatric Long-QT Syndrome With a Borderline QT Interval?

Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force–Guided Pulmonary Vein Isolation: Identifying the Weakest Link in the Ablation Chain Milad El Haddad, MSc, PhD; Philippe Taghji, MD; Thomas Phlips, MD; Michael Wolf, MD; Anthony Demolder, MD; Rajin Choudhury, MD; Sébastien Knecht, MD, PhD; Yves Vandekerckhove, MD; Rene Tavernier, MD, PhD; Hiroshi Nakagawa, MD, PhD; Matti...

متن کامل

Determinants of Acute and Late Pulmonary Vein Reconnection in Contact Force–Guided Pulmonary Vein Isolation

Catheter-based pulmonary vein isolation (PVI) is associated with a single procedure freedom from atrial fibrillation (AF) in ≈70% of patients with paroxysmal AF. Lack of durability of PVI, a major determinant of AF recurrence, is evidenced by acute PV reconnection at the time of the procedure and late pulmonary vein reconnection (PVR) during followup. The use of contact force (CF)–sensing cathe...

متن کامل

Contact force mapping during catheter ablation for atrial fibrillation: procedural data and one-year follow-up

INTRODUCTION Pulmonary vein isolation (PVI) is the state-of-the-art treatment of atrial fibrillation (AF). Pulmonary vein reconnection is one of the main mechanisms of AF recurrence after ablation. Catheter-tissue contact is essential for effective ablation lesions. The aim of this study was to evaluate the impact of catheter contact monitoring during PVI on AF recurrence rate. MATERIAL AND M...

متن کامل

Clinical implication of adenosine test at repeat atrial fibrillation ablation procedure: the importance of detecting dormant thoracic vein conduction.

BACKGROUND Pulmonary vein reconnection after electrical isolation is commonly observed in the context of atrial fibrillation ablation and is associated with recurrent atrial tachyarrhythmias. Adenosine test was been performed to identify acute dormant conduction immediately after pulmonary vein isolation at index procedure. However, the utility of adenosine test at repeat procedure has not been...

متن کامل

Acute pulmonary vein isolation is achieved by a combination of reversible and irreversible atrial injury after catheter ablation: evidence from magnetic resonance imaging.

BACKGROUND Pulmonary vein reconnection after pulmonary vein isolation is common and is usually associated with recurrences of atrial fibrillation. We used cardiac magnetic resonance imaging after radiofrequency ablation to investigate the hypothesis that acute pulmonary vein isolation results from a combination of irreversible and reversible atrial injury. METHODS AND RESULTS Delayed enhancem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 10 4  شماره 

صفحات  -

تاریخ انتشار 2017