Surgical left atrial appendage ligation is frequently incomplete: a transesophageal echocardiograhic study.
نویسندگان
چکیده
OBJECTIVES This study sought to determine the incidence of incomplete ligation of the left atrial appendage (LAA) during mitral valve surgery. BACKGROUND Ligation of the LAA to prevent future thromboembolic events is commonly performed during mitral surgery. However, success in completely excluding the appendage from the circulation has never been systematically assessed. METHODS Using transesophageal Doppler echocardiography, we studied 50 patients who underwent mitral valve surgery and ligation of the LAA. Thirty patients were studied immediately postoperative, and 20 patients were studied 6 days to 13 years after surgery. Incomplete ligation was detected by demonstrating a color jet traversing the separation between the left atrial body and appendage. RESULTS Transesophageal echocardiography detected incomplete LAA ligation in 18 of 50 (36%) patients. The incidence of incomplete ligation was not significantly different between patients studied immediately postoperative and patients studied at various times after surgery. Type of mitral surgery (repair vs. replacement), operative approach (sternotomy vs. port access), left atrial size or degree of mitral regurgitation did not significantly correlate with the incidence of incomplete appendage ligation. However, the power to detect a significant difference in left atrial size was only 64%. Spontaneous echo contrast or thrombus was identified within appendages in 9 of 18 (50%) patients with incomplete ligation, while 4 of these 18 (22%) patients had thromboembolic events. CONCLUSIONS Surgical LAA ligation is frequently incomplete. The similar incidence of incomplete ligation detected immediately postoperative and at various times thereafter suggest that this results from an intraoperative phenomenon rather than from gradual dehiscence of sutures over years. The incidence of incomplete left atrial ligation was unrelated to type of surgery, surgical approach, left atrial size or degree of mitral regurgitation. Residual communication between the incompletely ligated appendage and the left atrial body may produce a milieu of stagnant blood flow within the appendage and be a potential mechanism for embolic events.
منابع مشابه
The role of multimodality imaging in percutaneous left atrial appendage suture ligation with the LARIAT device.
Atrial fibrillation (AF), the most common cardiac arrhythmia, is a significant cause of embolic stroke. Although systemic anticoagulation is the primary strategy for preventing the thromboembolic complications of AF, anticoagulants carry major bleeding risks, and many patients have contraindications to their use. Because thromboembolism typically arises from a clot in the left atrial appendage ...
متن کاملRole of left atrial appendage obliteration in stroke reduction in patients with mitral valve prosthesis: a transesophageal echocardiographic study.
OBJECTIVES The aim of our study was to assess whether left atrial appendage (LAA) ligation in patients undergoing mitral valve replacement is associated with the risk of future embolisms. BACKGROUND Previous studies show that the LAA plays an important role in the development of intracardiac thrombus. According to this decisive role, LAA surgical closure in patients undergoing cardiac surgery...
متن کاملPercutaneous vascular plug for incomplete surgical left atrial appendage closure.
Surgical left atrial appendage (LAA) exclusion has a failure rate as high as 60% due to persistent residual flow in the LAA or large LAA remnants. We describe a novel technique for treatment of incomplete surgical LAA ligation, and define the mechanism that led to persistence of the remnant LAA without any thrombus formation.
متن کاملPericardial endoscopy-guided left atrial appendage ligation: a pilot study in a canine model.
BACKGROUND Approaches for closing the left atrial appendage (LAA) have been developed for stroke prevention. However, the prevailing maneuvers require an open-chest surgery, intravascular access, or transseptal puncture. We evaluated the feasibility and safety of pericardial endoscopy-guided LAA ligation in a canine model. METHODS AND RESULTS We used a total of 8 canines and computed tomograp...
متن کاملPercutaneous Closure of a Residual Left Atrial Appendage Leak After Lariat Procedure.
A 77-year-old man with long-standing persistent atrial fibrillation, coronary artery disease, and systolic heart failure underwent left atrial appendage (LAA) ligation with a Lariat suture delivery device (SentreHEART, Redwood City, California), and subsequent pulmonary vein isolation. One month after the ligation procedure, transesophageal echocardiogram (TEE) demonstrated a residual communica...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 36 2 شماره
صفحات -
تاریخ انتشار 2000