Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study
نویسندگان
چکیده
INTRODUCTION Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. METHODS 30 healthy young adults (age: 23±5 yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. RESULTS Comparison of RFD methods revealed that a peak 200 ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31-0.79). CONCLUSIONS Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations.
منابع مشابه
Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults
[Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric k...
متن کاملTest-retest reliability of hand-held dynamometry during a single session of strength assessment.
This retrospective study was undertaken to determine the test-retest reliability of hand-held dynamometer strength testing for 18 extremity muscle groups. To assess reliability, I compared three dynamometer strength scores recorded for each muscle group on the strength score forms of 30 neurologically involved patients, using the Pearson product-moment correlation and a one-way analysis of vari...
متن کاملComparison of maximal voluntary isometric contraction and hand-held dynamometry in measuring muscle strength of patients with progressive lower motor neuron syndrome.
Context. Maximal voluntary isometric contraction, a method quantitatively assessing muscle strength, has proven to be reliable, accurate and sensitive in amyotrophic lateral sclerosis. Hand-held dynamometry is less expensive and more quickly applicable than maximal voluntary isometric contraction. Objective. To investigate if hand-held dynamometry is as reliable and valid as maximal voluntary i...
متن کاملReliability of hand-held dynamometry and functional strength tests for the lower extremity in children with Cerebral Palsy.
PURPOSE To evaluate the intertester reliability of two methods for measuring lower-limb strength in children with cerebral palsy (CP). METHOD Twenty-five subjects with CP (7-17 years of age) participated in this study. Lower-limb muscle strength was measured on 2 occasions using a Hand-held Dynamometer (HHD; break-method and make-method) and a 30-sec Repetition Maximum (RM) during three funct...
متن کاملValidity and reproducibility of hand-held dynamometry in children aged 4-11 years.
OBJECTIVE To evaluate validity and reproducibility of hand-held dynamometry in 11 different muscle groups in children. DESIGN AND PATIENTS Maximum isometric muscle strength was measured with a calibrated hand-held dynamometer in 61 patients aged 4-11 years who had been referred to our specialist centre in the past 3 years because of suspected myopathy. All the patients had had muscle biopsy. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -