Does a tensioning device pinned to the tibia improve knee anterior-posterior load-displacement compared to manual tensioning of the graft following anterior cruciate ligament reconstruction? A cadaveric study of two tibial fixation devices.

نویسندگان

  • Dustin M Thompson
  • M L Hull
  • S M Howell
چکیده

Devices that are pinned to the tibia to tension an anterior cruciate ligament (ACL) graft produce joint reaction loads that in turn can affect the maintenance of graft initial tension after tibial fixation and hence knee anterior-posterior (AP) load-displacement. However, the effect of these devices on AP load-displacement is unknown. Our objectives were to determine whether tensioning by device versus tensioning by hand causes differences in AP load-displacement and intraarticular graft tension for two commonly used tibial fixation devices: a bioresorbable interference screw and a WasherLoc. AP load-displacement and intraarticular graft tension were measured in 20 cadaveric knees using a custom arthrometer. An initial tension of 110 N was applied to a double-looped tendon graft with the knee at extension using a tensioning device pinned to the tibia and a simulated method of tensioning by hand. After inserting the tibial fixation device, the 134 N anterior limit (i.e., anterior position of the tibia with respect to the femur with a 134 N anterior force applied to the tibia) and 0 N posterior limit (i.e., AP position of the tibia relative to the femur with a 0 N force applied to the tibia) were measured with the knee in 25 degrees flexion. Intraarticular graft tension was measured at extension. These limits and intraarticular graft tension were also measured after cyclically loading the knee 300 times. Compared to a simulated method of tensioning by hand, tensioning with a device pinned to the tibia did not decrease the 134 N anterior limit and did not cause posterior tibial translation. However, intraarticular graft tension was maintained better with a tensioning device pinned to the tibia for the Washerloc, but not the interference screw. For two commonly used tibial fixation devices, a tensioning device pinned to the tibia does not improve AP load-displacement at 25 degrees flexion over tensioning by hand when the graft is tensioned at full extension, but does improve the maintenance of intraarticular graft tension for the Washerloc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The impact of tensioning device mal-positioning on strand tension during Anterior Cruciate Ligament reconstruction

BACKGROUND In order to confer optimal strength and stiffness to the graft in Anterior Cruciate Ligament (ACL) reconstruction, the maintenance of equal strand tension prior to fixation, is desired; positioning of the tensioning device can significantly affect strand tension This study aimed to determine the effect of tensioning device mal-positioning on individual strand tension in simulated cad...

متن کامل

Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature

 Background: A rare and devastating complication following anterior cruciate ligament (ACL) revision reconstruction is femoral fracture.    Case presentation: A 35-year old male soccer player with a history of ACL tear from the previous year ago, who underwent arthroscopic ACL reconstruction and functioned well until another similar injury caused ACL re-rupture. Revision of ACL reconstruction w...

متن کامل

Multistranded hamstring tendon graft fixation with a central four-quadrant or a standard tibial interference screw for anterior cruciate ligament reconstruction.

BACKGROUND Tibial fixation of hamstring tendon grafts has been the weak link in anterior cruciate ligament reconstruction. HYPOTHESIS Use of a central four-quadrant sleeve and screw provides superior fixation when compared with standard interference screw fixation. STUDY DESIGN Controlled laboratory study. METHODS In eight pairs of cadaveric knees each anterior cruciate ligament was recon...

متن کامل

Combined Proximal and Distal Tibial Fixation in Posterior Cruciate Ligament Reconstruction

INTRODUCTION: Despite the recent advances in our understanding of the anatomy and biomechanics of the posterior cruciate ligament (PCL), current methods of PCL reconstruction continue to lack the clinical success that anterior cruciate ligament (ACL) reconstruction has experienced, with many patients developing residual posterior laxity following surgery [1]. One variable that directly affects ...

متن کامل

Single-tunnel double-bundle anterior cruciate ligament reconstruction with anatomical placement of hamstring tendon graft: can it restore normal knee joint kinematics?

BACKGROUND Anatomical reconstruction techniques that can restore normal joint kinematics without increasing surgical complications could potentially improve clinical outcomes and help manage anterior cruciate ligament injuries more efficiently. HYPOTHESIS Single-tunnel double-bundle anterior cruciate ligament reconstruction with anatomical placement of hamstring tendon graft can more closely ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic research : official publication of the Orthopaedic Research Society

دوره 24 9  شماره 

صفحات  -

تاریخ انتشار 2006