Effects of repetitive pulsing on multi-kHz planar laser-induced incandescence imaging in laminar and turbulent flames.

نویسندگان

  • James B Michael
  • Prabhakar Venkateswaran
  • Christopher R Shaddix
  • Terrence R Meyer
چکیده

Planar laser-induced incandescence (LII) imaging is reported at repetition rates up to 100 kHz using a burst-mode laser system to enable studies of soot formation dynamics in highly turbulent flames. To quantify the accuracy and uncertainty of relative soot volume fraction measurements, the temporal evolution of the LII field in laminar and turbulent flames is examined at various laser operating conditions. Under high-speed repetitive probing, it is found that LII signals are sensitive to changes in soot physical characteristics when operating at high laser fluences within the soot vaporization regime. For these laser conditions, strong planar LII signals are observed at measurement rates up to 100 kHz but are primarily useful for qualitative tracking of soot structure dynamics. However, LII signals collected at lower fluences allow sequential planar measurements of the relative soot volume fraction with a sufficient signal-to-noise ratio at repetition rates of 10-50 kHz. Guidelines for identifying and avoiding the onset of repetitive probe effects in the LII signals are discussed, along with other potential sources of measurement error and uncertainty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-dimensional imaging of soot volume fraction and OH in turbulent jet diffusion flames spanning low to high mixing rates

Simultaneous planar measurements of laser-induced incandescence (LII) and Laser-Induced Fluorescence of OH radical were carried out in turbulent jet flames from a simple jet, precessing jet and bluff body burner firing natural gas. These flames span a wide range of global mixing rates and sooting characteristics, and are selected because measurements of total NOx emissions, radiant fraction and...

متن کامل

Characterization of a CH planar laser-induced fluorescence imaging system using a kHz-rate multimode-pumped optical parametric oscillator.

The performance characteristics of a new CH planar laser-induced fluorescence (PLIF) imaging system composed of a kHz-rate multimode-pumped optical parametric oscillator (OPO) and high-speed intensified CMOS camera are investigated in laminar and turbulent CH4-H2-air flames. A multi-channel Nd:YAG cluster that produces up to 225 mJ at 355 nm with multiple-pulse spacing of 100 μs (corresponding ...

متن کامل

Quantitative three-dimensional imaging of soot volume fraction in turbulent non-premixed flames

A three-dimensional (3-D) imaging system for studies of reactive and non-reactive flows is described. It can be used to reveal the topology of turbulent structures and to extract 3-D quantities, such as concentration gradients. Measurements are performed using a high repetition rate laser and detector system in combination with a scanning mirror. In this study, the system is used for laserinduc...

متن کامل

Recent developments in laser-induced incandescence (LII) for soot diagnostics in high-pressure laminar flames and engine-like Diesel combustion

The analysis of soot formation and oxidation is essential for Diesel engine development to meet future pollutant emission reduction requirements. In recent years laser-induced incandescence (LII) has developed to a powerful tool for soot diagnostics in flames, even in the challenging environment of Diesel combustion. This work presents some recent applications of LII for soot particle sizing in...

متن کامل

Laser-induced incandescence and multi-line NO LIF thermometry for soot diagnostics at high pressures

Laser-induced incandescence (LII) is investigated in laminar premixed flat ethylene/air flames at pressures up to 5 bar in a recently constructed high-pressure burner. Time-resolved LII signals were compared with a numerical model considering the influence of pressure on the LII signal decay. Peak particle temperatures after laser heat up were measured by the detection of the LII signal at two ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 54 11  شماره 

صفحات  -

تاریخ انتشار 2015