Dislodgement resistance of modified resin-bonded fixed partial dentures utilizing tooth undercuts: an in vitro study

نویسندگان

  • Re-Mee Doh
  • Keun-Woo Lee
چکیده

STATEMENT OF PROBLEM Over the years, resin-bonded fixed partial dentures (RBFPDs) have gone through substantial development and refinement. Several studies examined the biomechanics of tooth preparation and framework design in relation to the success rate of RBFPDs and considered retention and resistance form essential for increase of clinical retention. However, these criteria required preparations to be more invasive, which violates not only the original intentions of the RBFPD, but may also have an adverse effect on retention due to loss of enamel, an important factor in bonding. PURPOSE The object of this in vitro study was to compare the dislodgement resistance of the new types of RBFPDs, the conventional three-unit fixed partial denture, and conventional design of RBFPD (Maryland bridge). MATERIAL AND METHODS Fifty resin mandibular left second premolars and second molars were prepared on dentiforms, according to the RBFPD design. After model fabrication (five group, n = 10), prostheses were fabricated and cemented with zinc phosphate cement. After cementation, the specimens were subjected to tensile loading at a cross head speed of 4 mm/min in a universal testing machine. The separation load was recorded and analyzed statistically using one-way analysis of variance followed by Duncan's multiple range test. RESULTS Group V, the pin-retained RBFPDs, had the highest mean dislodgement resistance, whereas specimens of group II, the conventional RBFPDs, exhibited a significantly lower mean dislodgement resistance compared to the other 4 groups (P < .05). There were no significant differences between group I, III, and IV in terms of dislodgement resistance (P > .05). Group V had the highest mean MPa (N/mm(2)) (P < .05). There was no significant difference between groups I, II, III and IV (P > .05). CONCLUSION Within the limits of the design of this in vitro study, it was concluded that: 1. The modified RBFPDs which utilizes the original tooth undercuts and requires no tooth preparation, compared with the conventional design of RBFPDs, has significantly high dislodgement resistance (P < .05). 2. The modified RBFPDs which utilizes the original tooth undercuts and requires minimal tooth preparation, compared with the conventional FPDs, has significantly no difference in retention and dislodgement resistance)(P > .05). 3. The pin-retained FPDs showed a high dislodgement resistance compared to the conventional three-unit FPDs (P < .05).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resin-bonded fixed partial dentures: what's new?

BACKGROUND AND OBJECTIVE Dentists often question the use of resin-bonded fixed partial dentures (RBFPDs) for reliable restoration of tooth-bound edentulous spaces. Initial attempts at bonding fixed partial dentures on teeth resulted in early failure due to debonding. In the 1980s and 1990s, improvements in preparation methods, metal alloys and bonding techniques made the RBFPD a more predictabl...

متن کامل

Minimally invasive preparation and design of a cantilevered, all-ceramic, resin-bonded, fixed partial denture in the esthetic zone: a case report and descriptive review.

UNLABELLED Resin-bonded, fixed partial dentures have the potential to offer a minimally invasive, fixed-prosthetic approach to tooth replacement in patients who may not be candidates for implant therapy. However, traditional preparation protocols often recommend extensive preparation designs on two abutment teeth, thereby potentially compromising the long-term health of the adjacent abutments a...

متن کامل

Single tooth replacement using a ceramic resin bonded fixed partial denture: A case report

This article describes the use of an all ceramic resin-bonded fixed partial denture as a conservative solution for the replacement of an incisor. It is a minimally invasive technique that does not discolor the abutment teeth.

متن کامل

Resin-bonded Bridge: Conservative Treatment Option for Single Tooth Replacement

Copyright: © 2013 Mittal S, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Abstract Resin-Bonded Fixed Partial Dentures (RBFPD) was introduced to dentistry around 40 years ago. The typical design of re...

متن کامل

Porcelain fused to metal crown as an abutment of a metal-ceramic resin-bonded fixed partial denture: a clinical report.

AIM This clinical report describes a conventional resin-based fixed partial denture for a 42-year-old woman to close an edentulous space in the region of the second maxillary premolar. While the first maxillary molar had been crowned with porcelain fused to metal (PFM) system 10 years ago and the first premolar was intact and sound except for a small carious lesion in the distal aspect. The ess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2009