A Real-Time Monitoring and Contamination Detection in Water Distribution Systems using 32-Bit Microcontroller

نویسنده

  • G. Vasudevan B. Sudhir Kumar
چکیده

-The aim of the Proposed Project is a Microcontroller based Low-Cost Sensor Network for Real-Time Monitoring and Contamination Detection in Potable and nonPotable Water Distribution Systems and also updates the information to the consumers and concerned authorities by using GSM module. In the existing system, it is just monitor the water level and electrical conductivity manually (off-line) and report to concerned authorities only in metropolitan areas. The objective of the p r o j e c t is to present a conceptual model of embedded based r e a l t i m e monitoring the water quality and also contamination detection for both potable and non-potable water distribution systems. In this proposed system we are using different sensors for water l e v e l and contamination detection. The main goal is the design and development of low cost system that can be used at the premises of consumers. This system can also be used in customer oriented manner to continuously monitor qualitative water parameters and fuse multi parametric sensor data for assessing the water quality.A 32-bit Microcontroller and associated sensor network can detect water contamination continuously according to water conductivity and temperature. Depends on these p a r a m e t e r s microcontroller computes the other related contaminants and transmits same data to consumers and some authorities by using GSM module. Our approach is based on the development of low cost sensor nodes for real time and in-pipe monitoring and assessment of water quality on the fly. The main sensor node consists of electrochemical and optical sensors which can be used to monitor the water quality. From the sensor node we are sending monitored values to control room (ARM board) through RS232 serial cable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Probabilistic Contaminant Source Identification in Water Distribution Infrastructure Systems

Large water distribution systems can be highly vulnerable to penetration of contaminant factors caused by different means including deliberate contamination injections. As contaminants quickly spread into a water distribution network, rapid characterization of the pollution source has a high measure of importance for early warning assessment and disaster management. In this paper, a methodology...

متن کامل

Performance Analysis of Open-Source Real Time Operating Systems

This paper presents the importance of analysis and evaluation of Performance Metrics of Real Time Operating systems. Advanced parameters such as Semaphore Shuffling Time, Deadlock Breaking Time, TaskTask message Passing Time are considered in this paper. A 32-bit Microcontroller is chosen for benchmarking. Two RTOS that are available as open source for educational purpose are considered. Index ...

متن کامل

Meeting real-time constraints using "Sandwich Delays"

In this paper, we are concerned with the development of software for a class of embedded systems in which there are two (sometimes conflicting) constraints. First, we wish to implement the design on a microcontroller with a cost of around $1.00 (US). This type of platform might include an 8-bit or 16/32-bit microcontroller with very limited memory and CPU performance. Second, we wish to produce...

متن کامل

Real-time acoustic tomography system and the experience of Caspian current sea monitoring

The Acoustic Tomography (AT) systems are used to monitor long-term and continuous flow in rivers, seas and oceans. One of the disadvantages of existing systems in Iran is the inability of real-time/automated measurements. In this study, by adding a raspberry Pi computer to the system and performing the required programming, it was possible to do online monitoring. The data are transferred to th...

متن کامل

LEAK DETECTION IN WATER DISTRIBUTION SYSTEM USING NON-LINEAR KALMAN FILTER

Leakage detection in water distribution systems play an important role in storage and management of water resources. Therefore, to reduce water loss in these systems, a method should be introduced that reacts rapidly to such events and determines their occurrence time and location with the least possible error. In this study, in order to determine position and amount of leakage in distribution ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015