Inadvertent cardiac phlebography
نویسندگان
چکیده
We are reporting a case of a 80-year-old lady with effort angina who underwent coronary angiography through the right radial artery, using a dedicated radial multipurpose 5 French Optitorque Tiger catheter. The catheter was advanced into the left ventricle and a left ventriculogram was obtained, while the catheter appeared optimally placed at the centre of the ventricle and the pressure waveform was normal. A large posterior interventricular vein draining into the right atrium was opacified, presumably because the catheter's end hole inadvertently cannulated an endocardial opening of a small thebesian vein, with subsequent retrograde filling of the epicardial vein. Our case suggests that caution is needed when a dedicated radial catheter with both an end-hole and a side hole is used for a ventriculogram, as a normal left ventricular pressure waveform does not exclude malposition of the end-hole against the ventricular wall.
منابع مشابه
A comparison between descending phlebography and duplex Doppler investigation in the evaluation of reflux in chronic venous insufficiency: a challenge to phlebography as the "gold standard".
To evaluate venous reflux in 56 lower limbs of 32 consecutive patients, hemodynamic tests, ascending and descending phlebography, and supine and erect quantitative duplex scanning were performed and the clinical severity was classified (class 0 = 15, class 1 = 19, class 2 = 8, and class 3 = 14). Of the 56 lower limbs, 22 (40%) had severe swelling and hyperpigmentation with or without ulcer (cla...
متن کاملComplications of ascending phlebography of the leg.
Forty patients were studied prospectively for complications of ascending phlebography. The commonest immediate complication was pain at the site of injection and the commonest delayed complication pain in the foot or calf. Out of 30 patients with pain in the foot and calf, 15 had venous thrombosis. Review of 200 case notes disclosed only one recorded complication--namely, necrosis of the dorsal...
متن کاملInadvertent triggering of the ventilator caused by surgically placed pacer wires.
Inadvertent ventilator triggering can occur for various reasons. Leaks in the ventilator circuit, endotracheal tube leaks, tracheal cuff leaks, cardiac oscillations, water condensate causing oscillations in the circuit tubing, ventilator expiratory valve integrity, and overly sensitive triggering mechanism settings may precipitate this phenomena. We present a case of inadvertent ventilator trig...
متن کاملImpedance Phlebography
Impedance phlebography, a noninvasive approach to the diagnosis of venous thrombosis, depends on decreasing calf electrical impedance in normal subjects during inspiration. In order to assess the relationship between impedance changes and inspiratory volume, normal subjects were studied at various depths of inspiration. The mean inspiration volume required for a result indicating no evidence of...
متن کاملCombined Radionuclide Phlebography and V/Q scan in the assessment of iliac vein thrombosis and pulmonary embolism – A case report establishing a cause and effect relationship
Deep vein thrombosis (DVT) is an important life threatening condition that is difficult to diagnose, particularly in the early stages. Looking for DVT in lower limb can be considered ancillary in suspected cases of pulmonary embolism (PE) indirectly highlighting a cause and effect relationship of a single disease (i.e cause being DVT and effect is the assault on the lung vasculature). Prompt an...
متن کامل