Non-pupillary block angle-closure mechanisms: a comprehensive analysis of their prevalence and treatment outcomes.

نویسندگان

  • Daniela L M Junqueira
  • Vitor G Prado
  • Flavio S Lopes
  • Luis Gustavo Biteli
  • Syril Dorairaj
  • Tiago S Prata
چکیده

PURPOSE To assess the prevalence and treatment outcomes of angle-closure mechanisms other than pupillary block in a population of Brazilian patients. METHODS A retrospective chart review was conducted to evaluate patients who had undergone laser peripheral iridotomy (LPI) due to occludable angles at a single institution between July 2009 and April 2012. An occludable angle was defined as an eye in which the posterior trabecular meshwork was not visible for ≥180° on dark-room gonioscopy. Key exclusion criteria were any form of secondary glaucoma and the presence of >90° of peripheral anterior synechiae. Collected data were age, race, gender, angle-closure mechanism (based on indentation goniocopy and ultrasound biomicroscopy), intraocular pressure (IOP), number of antiglaucoma medications and subsequent management during follow-up. If both eyes were eligible, the right eye was arbitrarily selected for analysis. RESULTS A total of 196 eyes of 196 consecutive patients (mean age 58.3 ± 11.6 years) who underwent LPI were included. In most of the patients [86% (169 patients; 133 women and 36 men]), LPI sucessfully opened the angle. Mean IOP was reduced from 18.3 ± 6.4 mmHg to 15.4 ± 4.5 mmHg after LPI (p<0.01). Among the 27 patients with persistent occludable angles, the most common underlying mechanisms were plateau iris (56%) and lens-induced component (34%). Most of these patients (85%) were treated with argon laser peripheral iridoplasty (ALPI); approximately 90% showed non-occludable angles following the laser procedure (mean IOP reduction of 18.9%), with no significant differences between patients with plateau iris and lens-induced components (p=0.34; mean follow-up of 11.4 ± 3.6 months). CONCLUSION Our findings suggest that, in this population of Brazilian patients, several eyes with angle closure were not completely treated with LPI. In the present large case series involving middle-age patients, plateau iris was the leading cause of persistent angle closure and was effectively treated with ALPI. A detailed eye examination with indentation gonioscopy should always be performed after LPI to rule out persistent angle closure due to non-pupillary block mechanisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angle-closure glaucoma: the role of the lens in the pathogenesis, prevention, and treatment.

Primary angle-closure glaucoma is a major cause of blindness worldwide. It is a disease of ocular anatomy that is related to pupillary-block and angle-crowding mechanisms of filtration angle closure. Eyes at increased risk for primary angle-closure are small with decreased axial length, anterior chamber depth, and filtration angle width, associated with a proportionately large lens. Angle-closu...

متن کامل

COVER STORY: ANGLE-CLOSURE GL AUCOM A Beyond relative pupillary block—identifying alternative mechanisms

D iagnostic tools for the detection of primary angle closure include old stalwarts such as gonioscopy and slit-lamp estimation of limbal anterior chamber depth1,2 as well as new technologies that yield high-resolution, cross-sectional images of the angle. In addition to their diagnostic potential, anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) have pro...

متن کامل

Pseudophakic angle-closure from a Soemmering ring

BACKGROUND Report of three patients with pseudophakic angle-closure from a Soemmering ring. Three mechanisms of the Soemmering ring induced pseudophakic angle-closure in three patients were demonstrated by meticulous anterior segment examination and ultrasound biomicroscopic (UBM) analysis. CASE PRESENTATION In the first case, the Soemmering-capsule-IOL complex caused relative pupillary block...

متن کامل

Qualitative evaluation of anterior segment in angle closure disease using anterior segment optical coherence tomography

PURPOSE To evaluate different mechanisms of primary angle closure (PAC) and to quantify anterior chamber (AC) parameters in different subtypes of angle closure disease using anterior segment optical coherence tomography (AS-OCT). METHODS In this prospective study, 115 eyes of 115 patients with angle closure disease were included and categorized into three groups: 1) fellow eyes of acute angle...

متن کامل

Surgical management of chronic angle-closure glaucoma

Chronic angle-closure glaucoma is a major cause of blindness, particularly in Asia. The goals of management are to prevent both progression of anatomic angle-closure and progression of glaucomatous optic neuropathy, the latter by controlling intraocular pressure. Laser iridotomy to eliminate pupillary block is the definitive initial treatment and laser peripheral iridoplasty is the second-line ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 77 6  شماره 

صفحات  -

تاریخ انتشار 2014